2 Operational safety 2.9 ESD guidelines 24 User Manual SIPLACE Nozzle Cleaning Station 09/2019

100%1 / 72
2 Operational safety
2.9 ESD guidelines
User Manual SIPLACE Nozzle Cleaning Station 09/2019 23
2.9.5 Dispatching ESD modules
Always store modules and components in conductive packaging (e.g. metallized plastic bags
or metal sleeves) and dispatch them in conductive packaging
If the packaging is not conductive, place the modules in a conductive envelope before pack-
aging. Use conductive expanded rubber, ESD bags, domestic aluminum foil or paper, for
example. NEVER use plastic bags or film.
If the module has integral batteries, ensure that the conductive packaging does not touch or
short circuit the battery terminals and, if necessary, first cover the terminals with insulating
tape or material.
2 Operational safety
2.9 ESD guidelines
24 User Manual SIPLACE Nozzle Cleaning Station 09/2019
3 Technical data and assemblies
3.1 Performance data
User Manual SIPLACE Nozzle Cleaning Station 09/2019 25
3 Technical data and assemblies
3.1 Performance data
The cleaning performance is independent from the nozzle type to be cleaned. It is determined
solely by the cleaning cycle of the nozzle tip and nozzle shaft cleaning module.
The NCS has 3 cleaning cells in which the cleaning of the nozzle tip and nozzle shaft runs parallel.
Thus every 5 minutes cleaned nozzles can be removed from the NCS.
Head Nozzle magazine Cleaned nozzle / 5min
C&P20 A/M Magazine complete 10xx [03016831‑xx]
1)
36
C&P20 P/M2/P2 Nozzle magazine type 40xx [03101503‑xx]
2)
54
CPP Nozzle magazine type 20xx [03066107‑xx] 12
CPP/M Nozzle magazine type 20xx/20 [03130933‑xx] 60
1)
Upgrade of locking mechanism required, see 3.1.2 "Cleaning with C&P20A nozzle magazines" [}26]
2)
Only 18 from 20 nozzle can be cleaned, see 3.1 "Performance data" [}25]
3.1.1 Cleaning with C&P20 P nozzle magazines
Due to the technical design of the CP20P magazines there are no openings below 2 of the 20
nozzles. Without these holes cleaning is not possible. Therefor the cleaning for CP20P nozzle
magazines was modified to clean 18 nozzles only.
Fig.8: Nozzle magazine type 40xx [03101503‑xx] – Positions where cleaning is not possible