吸嘴自动检查NozzleHealthCheck_E.pdf - 第10页

Product Engineering Division SMT Section IM Operations Y AMAHA MOTOR CO., L TD MDOC-SOFT50394 10/2 1 3.7 Operation con tr ol W hen the [Setup] - [Software S etting] - [Health Chec k] - [Don’t s tart running if Nozzle Hea…

100%1 / 21
Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50394
9/21
3.6 Details of result
Select a nozzle indicated in red on the result screen, and press the [Result Detail] button. The
details of the NG contents are displayed. In the veiw on the right shows an image of the NG
nozzle.
Images are saved only when it is set to do so on [Software Setting] – [Health Check].
Images are taken only at Tip Dirt Check, Shape Check, or Alignment Check.
View from the bottom
View from the side
Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50394
10/21
3.7 Operation control
When the [Setup] - [Software Setting] - [Health Check] - [Don’t start running if Nozzle Health
Check NG is detected.] check box is checked, auto-running does not start as long as Nozzle
Health Check is not completed, or used nozzle is judged as “NG”.
When auto-running does not start, clean or exchange the NG nozzle, and perform Nozzle
Health Check again.
In the Nozzle Health Care function, when the [Don’t start running if Nozzle Health Check NG is
detected.] check box is checked, the abnormal nozzles are replaced with spare nozzles. If there
is no available spare nozzle, auto-running is suppressed.
When the [Don’t start running if Nozzle Health Check NG is detected.] check box is not checked,
the abnormal nozzles are not replaced with spare nozzles, auto-running is not suppressed.
4
3.8 Save log file
When [Setup] - [Software Setting] - [Health Check] - [Save log file] check box is checked, log file
is saved to [Output Path] folder.
Log file name is NHCLog_(Machine serial number)_(Mount table Number)_YYYYMMDD.csv”.
(Example: NHCLog_Y20000_A_20150315.csv)
When either of following is performed, results of [Vacuum Check], [Nozzle Tip Dirt Check],
[Nozzle Buffing Check], [Nozzle Shape Check], [Nozzle Alignment Check] are output to log file.
Non-checked nozzle is not output to log file.
1. Tap [Health Check] button.
2. Tap either of [Vacuum check], [Nozzle Tip Dirt Check], [Nozzle Buffing Check], [Nozzle
Shape Check], [Nozzle Alignment Check] button.
3. Perform schedule spec.
Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50394
11/21
Table3.2 Format of log file
No.
Item Name Explanation
1
Date
Year, month, day, hour, minute, second when output.
2
Table No
Mount table name
3
Head No
Head number
4
Nozzle Type
Nozzle type name
5
Nozzle Station
Nozzle station number
6
Execute Trigger
Check timing
“NHC”: When executed from [Health Check] button.
“UTL”: When executed from each button.
“SCH”: When executed from schedule spec.
7
Vacuum Check
Result of Vacuum Check.
([OK] or [NG]. Empty when does not performed)
8
Tip Dirt Check
Result of Nozzle Tip Dirt Check.
([OK] or [NG]. Empty when does not performed)
9
Buffing Check
Result of Nozzle Buffing Check.
([OK] or [NG]. Empty when does not performed)
10
Shape Check
Result of Nozzle Shape Check.
([OK] or [NG]. Empty when does not performed)
11
Alignment Check
Result of Nozzle Alignment Check.
([OK] or [NG]. Empty when does not performed)
12
[Vacuum]Vacuum Level
Result of vacuum level.
(Only when vacuum check is executed)
13
[Vacuum]Pick Low Level
Value of [Machine] - [Machine Data] - [Head] - [Vacuum
Level] - [Low Level].
(Only when vacuum check is executed)
14
[Vacuum]Pick High Level
Value of [Machine] - [Machine Data] - [Head] - [Vacuum
Level] - [High Level].
(Only when vacuum check is executed)
15
[Vacuum]Detection Rate
Detection Rate(%) = ( Vacuum Level - Low Level ) / (High
Level - Low Level ) * 100
(Only when vacuum check is executed)
16
[Vacuum]Error Detection
Rate
Value of [Machine] - [Specification Information] - [Schedule
Specification] - [Vacuum Check] - [Error Detection Rate].
(Only when vacuum check is executed)
17
[Shape]Measurement[um]
Measure result of nozzle tip length.
(Only when Nozzle Shape Check is executed)
18
[Shape]Upper Limit[um]
“The design value under a nozzle tip length(um) The
error under a nozzle tip length(um)” value of [Machine] -
[Specification Information] - [Side View Camera Spec] -
[Nozzle Basic Setting].
(Only when Nozzle Shape Check is executed)
19
[Shape]Lower Limit[um]
“The design value under a nozzle tip length(um)” - “The
error under a nozzle tip length(um)” value of [Machine] -
[Specification Information] - [Side View Camera Spec] -
[Nozzle Basic Setting].
(Only when Nozzle Shape Check is executed)
20
[Alignment]X-gaps[mm]
Measure result of nozzle gap X
(Only when Nozzle Alignment Check is executed)