Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50394
18/21
7576
Abnormal Vacuum
Detected.
Detection Rate (%) is larger than Error Detection Rate
(%).
A nozzle may be clogged.
・Clean or change the nozzle and shaft.
・Confirm the value of Error Detection Rate on [Setting] -
[Specification Information] - [Mount Nozzle Specification]
- [Nozzle Data].
・Confirm the Low level and High level of [Setting] -
[Machine Data] - [Head] - [Vacuum Level].
* For details of "Detection Rate" and "Error Detection
Rate", refer to the [Detail] tab.
------------------------------------------------
- "Detection Rate" means "clog level" of a nozzle,
compared to the difference between "Max Vacuum Level"
and "Min Vacuum Level" as 100.
Detection Rate(%) = ( Current Vacuum Level - Min
Vacuum Level ) / ( Max Vacuum Level - Min Vacuum
Level ) ×100
- "Min Vacuum Level" means Low Level, and "Max
Vacuum Level" means high level.
- The error occurs when "Detection Rate" is over "Error
Detection Rate".
7577
Nozzle tip dirt detected. Abnormality detected on the tip of a nozzle.
It may be unclean or damaged.
7578
Abnormal nozzle buffing
detected.
There is something wrong with the nozzle buffing.
The buffing may be unclean, sticky, or jammed.

Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50394
19/21
7579
Abnormal nozzle shape
detected.
There is something wrong attached on a nozzle.
Clean or change it.
7580
Abnormal nozzle
alignment detected.
Misalignment of nozzle tip position is over the correction
limit.
The nozzle may be damaged, unclean, or skewed.
7581
Unable to perform
nozzle health check.
It is necessary to read board data, when "ManualNzlChg"
is selected.
Read board data, or
Select "AutoNzlChg" on [Machine] - [Machine Data] -
[Head] - [Head Offset].
7584
Board data has been
edited.
Save and reload the board data to apply the changes.

Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50394
20/21
7585
Nozzle Health Check
failed
Check the conditions below and try it again.
・Execute [Unit] - [Head] - [Nozzle Change] and confirm
the nozzle is successfully changed.
・Execute [Unit] - [Head] - [Cleaning Blow] and confirm
the cleaning blow is successfully performed.
・Settings of each nozzle check (*) are correct.
(For details, refer to the operation manual.)
* “Each nozzle check” means the following items of
Nozzle Health Check.
・Vacuum Check
・Nozzle Tip Dirt Check
・Nozzle Buffing Check
・Nozzle Shape Check
・Nozzle Alignment Check
7590
Nozzle Health Check
Execution Error
Unable to execute Nozzle Health Check with [board data
nozzle] because the board data has an error.
Reload the board data and remove the cause of the error.
7591
Nozzle Health Check
Execution Error
Unable to execute Nozzle Health Check with [board data
nozzle] because board data is not read.
Read board data.
7592
Nozzle Health Check
Execution Error
Unable to execute Nozzle Health Check with [NG Nozzle]
because there is no NG nozzle.