00196351-06_UM_ACT_DE_EN.pdf - 第101页

ACT - Accurac y Check Tool / User Manual 09/2015 Edition 11 Figure 2-4: Manual waffle pack tray holder for S-table (carrier) f or the glass components Figure 2-5: Manual waffle pack tray holder for X-table (carrier) f or…

100%1 / 184
ACT - Accuracy Check Tool / User Manual 09/2015 Edition
10
2.2.2 Individual Components in the ACT Set
Measuring plate (glass plate) in metal frame (Figure 2-1 and Figure 2-2):
The glass components and the measuring plate are kept in a storage case.
Figure 2-1: Storage case for measuring plate Figure 2-2: Storage case for glass components
The glass components used for ACT are placed in the milled divisions in the waffle pack tray
(Figure 2-3).
Figure 2-3: Waffle pack tray for glass components
Key:
(1) Waffle pack tray
(2) Waffle pack tray carrier
(3) Glass components
ACT - Accuracy Check Tool / User Manual 09/2015 Edition
11
Figure 2-4: Manual waffle pack tray holder for S-table (carrier) for the glass components
Figure 2-5: Manual waffle pack tray holder for X-table (carrier) for the glass components
Figure 2-6: Measuring plate for ACT
ACT - Accuracy Check Tool / User Manual 09/2015 Edition
12
3 Preparatory Work
3.1 General Hardware Preparations
Ensure that the glass components are placed correctly in the divisions. The components should
be placed face downwards into the tray, see Figure 3-1.
Figure 3-1: Arrangement of the glass components; vacuum nozzle HANDI-VAC
NOTICE
Handling the glass components
Do not touch the underside of the glass surface where the QFP structure is applied
when you handle the glass components.
Use the "HANDI VAC HV-4-ESD" vacuum nozzle [00334547-xx] to suck the
components on the upside where name and serial number are imprinted.
Feeder for ceramic components (Cerampads)
Figure 3-2: Feeder for ceramic components (S-feeder in figure)
Key: