47 Technical Data Electrical Ratings and Compressed Air Supply Electrical ratings Supply voltage 3 x 200 V~ ± 5 %; 50/60 Hz (Japan) 3 x 208 V~ ± 5 %; 50/60 Hz (U.S.A.) 3 x 230 V~ ± 5 %; 50/60 Hz 3 x 380 V~ ± 5 %; 50/60 H…

46
Technical Data
SMEMA Interface - Signal Sequence
1. After switching on the station
Transport direction
Belt n Belt n+1
PCB sensor PCB sensor
Station n transports PCB
to the transfer position
Belt n running Belt n+1 stopped
BOARD AVAIL-
ABLE
Permission
Station n+1
is not ready
1
0
2. The PCB transfer has started
Transport direction
Belt n Belt n+1
PCB sensor
Station n transfers
PCB to Station n+1
Belt n running Belt n+1 running
Station n+1 expects
PCB from station n
3. PCB is transferred
Transport direction
Belt n Belt n+1
PCB sensor PCB sensor
Station n has
just transferred the PCB
Belt n stopped Belt n+1 running
Station n+1 expects PCB
from station n, but PCB
has not yet arrived.
PCB sensor
4. PCB transfer is complete
Transport direction
Belt n Belt n+1
PCB sensor PCB sensor
Station n
Belt n stopped Belt n+1 running
Station n+1
PCB arrived
Request
NOT READY
BOARD AVAIL-
ABLE
Permission
1
1
Request
NOT READY
BOARD AVAIL-
ABLE
Permission
0
1
Request
NOT READY
BOARD AVAIL-
ABLE
Permission
0
0
Request
NOT READY
To start a new PCB transfer, both signals must be "0" for at least 50 ms.

47
Technical Data
Electrical Ratings and Compressed Air Supply
Electrical ratings
Supply voltage 3 x 200 V~ ± 5 %; 50/60 Hz (Japan)
3 x 208 V~ ± 5 %; 50/60 Hz (U.S.A.)
3 x 230 V~ ± 5 %; 50/60 Hz
3 x 380 V~ ± 5 %; 50/60 Hz
3 x 400 V~ ± 5 %; 50/60 Hz (Europe)
3 x 415 V~ ± 5 %; 50/60 Hz
Fuse protection (machine) 3 x 32 A (3 x 200 V~ / 3 x 208 V~ / 3 x 230 V~)
3 x 16 A (3 x 380 V~ / 3 x 400 V~ / 3 x 415 V~)
Mains connection
(machine)
Cable 5 x 6 mm² with CEKON connector 5 x 32 A (3 x 200 V~ / 208 V~ / 230 V~)
Cable 5 x 4 mm² with CEKON connector 5 x 16 A (3 x 380 V~ / 400 V~ / 415 V~)
Fuse protection (SWS)
3 x 16 A (3 x 208 V~ / 3 x 230 V ~ / 3 x 380 V~ / 3 x 400 V~ / 3 x 415 V~)
Mains connection (SWS)
a
a) 1 mains connection required per SWS.
Cable 4 x 2.5 mm² with CEE connector 5 x 16 A (400 V~)
Nominal apparent power
SIPLACE CA4: 5.0 kVA
SWS: 0.7 kVA
Rated current consump-
tion
SIPLACE CA4: 11.3 A / 3 x 400 V~
SWS: approx. 1.8 A / 3 x 400 V~
Compressed air supply
Compressed air pressure
values
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connec-
tion
R 3/4" inner thread (pipe thread) with 1/2" hose connection
Compressed air consumption
a
Placement head configuration Compressed air
consumption
b
with vacuum pump
Compressed air
consumption
without vacuum
pump
c
SIPLACE CA 4
C&P20 M/C&P20 M/C&P20 M/C&P20 M
C&P20 M / C&P20 M / CPP / CPP
CPP / CPP / CPP / CPP
C&P20 M / C&P20 M / CPP / TH
CPP / CPP / CPP / TH
220 Nl/min
370 Nl/min
480 Nl/min
350 Nl/min
460 Nl/min
960 Nl/min
7200 Nl/min
480 Nl/min
700 Nl/min
460 Nl/min
Compressed air specification
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content
(class 1)
Particle density 0.01 mg/m³
Pressure dewpoint
(class 4)
Dewpoint + 3°
a) Average consumption values.
b) Under normal atmospheric conditions at 20°C and 1013 hPa.
c) Optional

48
Technical Data
Electrical Connection and Interfaces
12
43
PC and LAN
connection
Mains connection for machine
Cable 5 x 6 mm² with CEKON connector 5 x 32
A (3 x 208 V~ / 3 V~ / 230 V~)
or
Cable 5 x 4 mm² with CEKON connector 5 x 16 A
(3 x 380 V~ / 3 x 400 V~ / 3 x 415 V~)
Compressed air connection
SMEMA/Siemens interface
Mains connection per SWS
Cable 5 x 4 mm² with CEKON connector 5 x 16 A (3x 380
V~ / 3x 400 V~ / 3x 415 V~)