4OM-1610-002_w.pdf - 第196页
4OM-1610 3-49 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 42b107 Time-out of Shuttle Conveyor in Input side PCBis detectedfromStopSensorafternishingcompletel…

4OM-1610
3-48
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
42a201 Time-out of Shuttle Conveyor in Input side
Time-out is occurred during insert mode from Input Machine.
There is a possibility that PCB is stopped on conveyor.
1. Please
conrmPCBposition.
2. PleaseconrmwhetherConveyorWidthist.
3. Please setup Input Conveyor Timer Value of System settings, and adjust
insert time.
42a202 Time-out of Shuttle Conveyor in Input side
Time-out is occurred during insert mode for Inner Machine.
PCBis
stoppedonConveyor.PleaseconrmPCBPosition.
1. PleaseconrmwhetherTransitPositionfromshuttleConveyorisproper.
2. PleaseconrmwhetherConveyorWidthist.
42a203 Time-out of Shuttle Conveyor in Input side
Time-out is occurred while Delivery Position from Input Machine is being moved.
Pleaseconrm
whetherthereisnoerrorinUnit,nointerferenceornot.
42a204 Time-out of Shuttle Conveyor in Input side
Time-out is occurred while Transfer position is being moved to Inner Machine.
Pleaseconrm
whetherthereisnoerrorinUnit,nointerferenceornot.
42a301 Time-out of Shuttle Conveyor in Input side
Error is made while Shuttle Conveyor is working.
-----
42b101 Time-out of Shuttle Conveyor in Input side
Decrease Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42b102 Time-out of Shuttle Conveyor in Input side
Decrease Sensor is not detected before starting to operate.
PCB to output is not found.
1. Please
conrmwhetherPCBisdetectedbySensor.
2. ThereisapossibilitythatPCBisdropping.PleaseconrmwhetherConveyor
Widthistornot.
42b103 Time-out of Shuttle Conveyor in Input side
Stop Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42b104 Time-out of Shuttle Conveyor in Input side
Stop Sensor is not detected before starting to operate.
PCB to output is not found.
1. Please
conrmwhetherPCBisdetectedbySensor.
2. There is a possibility that PCB is dropping.
PleaseconrmwhetherConveyorWidthistornot.
42b105 Time-out of Shuttle Conveyor in Input side
PCBis
detectedfromDecreaseSensorafternishingcompletely.
Please remove PCB from Shuttle Conveyor.
42b106 Time-out of Shuttle Conveyor in Input side
PCBis
notdetectedfromDecreaseSensorafternishingcompletely.
PleaseconrmwhetherPCBisdetectedproperly.AndconrmwhetherSensor
did not break down.
1011-002

4OM-1610
3-49
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
42b107 Time-out of Shuttle Conveyor in Input side
PCBis
detectedfromStopSensorafternishingcompletely.
Please remove PCB from Shuttle Conveyor.
42b108 Time-out of Shuttle Conveyor in Input side
PCBis
notdetectedfromStopSensorafternishingcompletely.
PleaseconrmwhetherPCBisdetectedproperly.AndconrmwhetherSensor
did not break down.
42b109 Time-out of Shuttle Conveyor in Input side
PCB is detected from Shuttle Conveyor.
Please remove PCB from Conveyor.
42b10a Time-out of Shuttle Conveyor in Input side
PCB is not detected from Shuttle Conveyor.
Pleaseconrm
whetherPCBisdetectedproperly.AndconrmwhetherSensor
did not break down.
42b10b Time-out of Shuttle Conveyor in Input side
PCB has not got to shuttle Conveyor from Inner Machine.
PCB from Input Machine is not transferred.
Pleaseconrm
whetherPCBontheconveyorforInputmachineiscaught
42b10c Time-out of Shuttle Conveyor in Input side
PCB is still on Shuttle Conveyor.
Output for Output Machine has not completed.
Pleaseconrm
PCBposition.
42b10d Time-out of Shuttle Conveyor in Input side
PCB on Shuttle Conveyor is gone.
It is possible to operate continuously.
Pleaseconrm
whetherPCBwentoffitspositionifPCBisnotremovedon
purpose.
42b10e Time-out of Shuttle Conveyor in Input side
PCB on Shuttle Conveyor is changed.
PCB is inserted while not possible to be inserted. Please remove inserted PCB.
42b10f Time-out of Shuttle Conveyor in Input side
The Sensor of Shuttle Conveyor is detected from both sides.
There is a possibility that two pieces of PCB are inserted. Please remove an
uncertain PCB.
42b201 Time-out of Shuttle Conveyor in Output side
Time-out is occurred during insert mode from inner Machine.
There is a possibility that PCB is stopped on conveyor.
1. Please
conrmPCBposition.
2. PleaseconrmwhetherConveyorWidthist.
3. Please setup Input Conveyor Timer Value of System settings, and adjust
insert time.
42b202 Time-out of Shuttle Conveyor in Output side
Time-out is occurred during Output Mode for Output Machine.
PCB is stopped between Conveyors. Check out PCB position.
1. Please
conrmwhetherTransitpositionfromshuttleconveyorisproper.
2. PleaseconrmwhetherConveyorWidthist.
1011-002

4OM-1610
3-50
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
42b203 Time-out of Shuttle Conveyor in Output side
Time-out is occurred while Transfer position from Inner Machine is being moved.
Pleaseconrm
whetherthereisnoerrorinUnit,nointerferenceornot.
42b204 Time-out of Shuttle Conveyor in Output side
Time-out is occurred while Delivery Position is being moved to Output Machine.
Pleaseconrm
whetherthereisnoerrorinUnit,nointerferenceornot.
42b301 Shuttle Conveyor Error in Output side.
Error is made while Shuttle Conveyor is working.
-----
T4C5
1011-002