speedline 680SD Pump .pdf - 第15页
. . . . . 680SD BRUSHL ESS SERVO PUM P Dispe nsing Ope rati on and Main tenance Gui de 13 Dispensing Int roduct ion This sec ti on prov ides information about ne edles used on the 680S D pump , describes factors that aff…

680SD BRUSHLESS SERVO PUMP
Fine Tuning Lift Height
12 680SD Brushless Servo Driven Pump
Fine Tuning Lift Height
Introduction If material flow through the pump is either insufficient or excessive after purging, you
will need to adjust the lift height in order to achieve the correct volume of material.
Procedure Adjust the lift height as follows:
1. While selecting the Purge On button, rotate the adjustment ring clockwise (to
decrease volume) or counter-clockwise (to increase volume) until satisfactory
flow is achieved.
2. When the desired volume is achieved, rotate the adjustment an additional ½ turn
and then back to the desired setting to eliminate any backlash.
3. Tighten the lock screw.

.
.
.
.
.
680SD BRUSHLESS SERVO PUMP
Dispensing
Operation and Maintenance Guide 13
Dispensing
Introduction This section provides information about needles used on the 680SD pump, describes
factors that affect dispensing, and provides recommendations for dispensing.
In this Section Refer to the following:
Topic See Page
Dispensing Needles 14
Factors that Affect Dispensing 15
Dispensing Recommendations 15

680SD BRUSHLESS SERVO PUMP
Dispensing Needles
14 680SD Brushless Servo Driven Pump
Dispensing Needles
Description
Attention
Needles that are used on the 680SD pump are not interchangeable with needles
used on other pumps. The leadscrew ball seats in the needle to shut off material flow
and establishes the lift height (ZERO). Damage to the leadscrew will result if the
proper needles are not used.
The pump is designed to be used with unique stainless-steel needles. A variety of
needle sizes are supplied with the pump.