680SD BRUSHL ESS SERVO PUM P Inst allat ion P rocedures 2 680SD B rushless Servo Dri ven Pump Ins t alla tion Pro ced ure s Int roduct ion The 680SD pump is moun ted directly to the Flex Dispenser Z -axis mount ing plate…

Operation and Maintenance Guide 1
.
. .
. .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
680SD Brushless Servo Pump
Overview
Introduction This manual describes how to install, operate and maintain the 680SD Brushless
Servo Pump. The CAMALOT 680 SD Servo Driven Brushless pump is a liquid/semi
liquid, precision dispensing device. It is typically used for encapsulation and underfill
operations. The pump is comprised of servo driven brushless motor, a rotary
leadscrew and cartridge assembly, main body housing with a Luer fitting to except
dispense material syringes.
Theory of Operation Dispensing of material is accomplished by using air pressure to provide a constant
supply of material to the leadscrew. Air pressure is also applied to an integral air
cylinder to raise the leadscrew and open the dispense port, thereby allowing the flow
of material through the needle.
Servo control is used to provide a means of varying the speed of the pump motor. The
motor RPM is programmable and turns on and off under program control. It does not
run continuously.
Control of dispense drip or leaking while the leadscrew is not turning is accomplished
by removing air pressure from the integral cylinder and allowing the leadscrew which
has a machined ball on the end to return from the dispense position, sealing off the
reservoir end of the needle.
In this Manual The following is covered:
Topic See Page
Installation Procedures 2
Pump Setup 8
Dispensing 13
Pump Maintenance 16
Support Kit and Spare Parts 27
Parts List 28

680SD BRUSHLESS SERVO PUMP
Installation Procedures
2 680SD Brushless Servo Driven Pump
Installation Procedures
Introduction The 680SD pump is mounted directly to the Flex Dispenser Z -axis mounting plate
using the supplied Z-axis mounting adapter.
In this Section Refer to the following:
Topic See Page
Installing a Needle 3
Mounting the Pump 4
Electrical Connection 5
Pump Pneumatic Connections 6
Syringe Air Connections 7

.
.
.
.
.
680SD BRUSHLESS SERVO PUMP
Installing a Needle
Operation and Maintenance Guide 3
Installing a Needle
Procedure Reference Figure 7 when performing the following:
Attention
The needle can be installed with the pump on or off the machine.
1. Unscrew the needle holder nut from the bottom of the pump cartridge.
2. Drop a needle into the needle holder nut and thread the assembly onto the bot-
tom of the cartridge. Make sure that the needle is centered within the needle
holder nut. While turning the nut, a spring tension, created by the self-centering
action of the leadscrew, will be felt.
3. Tighten the needle holder nut (by hand only) until the assembly is tight.