4OM-1064-001.pdf - 第17页
Tg0249-PM-MM 3. Maintenance Spots (Overall) 0103-003 1-7 A A’ Fig. 1.4 Beam B Side (Front Side of Machine) Control Box Empty T ape Box V acuum Pressure System Sectional View A-A ’ Component Recognition Section PCB Positi…

Tg0249-PM-MM
Fig. 1.2
3. Maintenance Spots (Overall)
9910-001 1-6
Component Supply Section
Beam A Side
Beam B Side
Fig. 1.3
3. Maintenance Spots (Overall)
Air Regulator
Multi-Layer Tray Feeder
(Option)
Component Supply Section
Multi-Layer Tray Feeder
(Option)
Beam A Side

Tg0249-PM-MM
3. Maintenance Spots (Overall)
0103-003 1-7
A
A’
Fig. 1.4
Beam B Side
(Front Side of Machine)
Control Box
Empty Tape Box
Vacuum Pressure System
Sectional View A-A’
Component Recognition Section
PCB Positioning Section
Beam B (X/Y Beam)
Nozzle Stocker
Placement Heads
Conveyor
Traverses
Beam, A (X/Y Beam)
Nozzle Stocker
Feeder Base
Placement Heads
Rejected Component
Storage Box
Teaching Plate Section
Fig. 1.5
Feeder Base
Rejected Component
Storage Box

Tg0249-PM-MM1-8
Table 1.4
4. Daily Maintenance
4. Daily Maintenance
Vacuum Pump
Checking
Check the vacuum pressure visually.
Vacuum valve fully closed:
Min.-93kPa (Min.70cmHg) or more
During Operation:
Min.-60kPa (Min.45cmHg) or more
Fig. 1.6 Air Regulator
Fig. 1.7 Vacuum Pressure System
Maintenance Spots Check
Name
Fig.
No.
Description
Grease
Cleaning
Tools,
Nozzles, etc.
Air Regulator Main Air 1.6 Checking
Air Blowing 1.6 Checking
Vacuum Pressure
System
Vacuum Pump 1.7 Checking
Empty Tape Box 1.8 Abandonment Scrap Box
Component Discharge
Box
1.9 Abandonment
Feeder Base Upper Surface of
Feeder Base
1.9 Cleaning
Component
Supply Section
(Feeder)
Whole Body of Tape
Feeder
1.10 Checking and Cleaning
Air Blowing
Checking
Check the air pressure visually.
0.015 MPa (0.15 kgf/cm
2
)
Main Air
Checking
Check the air pressure visually.
0.49 MPa (5 kgf/cm
2
)
Beam A Side
Beam B Side
0004-002