1. Changing a Syringe
Purpose
Replace a syringe when the glue runs out, or when a different type of adhesive must be
used.
Procedure
Removal
1. Use the inching operation to inch the syringe head to the center of the machine
where it is easily accessible, then press the EMERGENCY STOP button and cut the
power to the machine.
2. Turn the cap nut clockwise as viewed from above and remove it.
3. Remove the syringe assembly from the head as described below.
(1) While pressing the head down with one hand to keep the glue-level check
sensor out of the way, use the other hand to lift the syringe fixing ring
(black) several millimeters. (Lift until the ring's lock pins detach from the
syringe tab.)
Note: The syringe fixing ring is held onto the syringe holder by a magnet.
(2) Rotate the syringe assembly leftward 90 degrees, then pull the assembly
upward to remove it from the syringe holder.
Note: While lifting the syringe assembly, use one hand to push upward on the
needle side to prevent the adaptor from dropping off.
GL541-m76E
2
1
3
4
Glue-level
check sensor
Cap nut
Syringe
fixing ring
Lock pins
Needle
Syringe holder
Adaptor
Syringe assembly
Press
head down
Chapter 3 Changeover
Version 3.6 3-1-1 GL-541E Maintenance
4. Lift off the rotary joint locking flange, then rotate the syringe approximately 90
degrees to detach it from the rotary joint.
5. Use a pair of needle nose pliers to remove the float from the syringe as shown
below.
Installation
1. Insert the float into the syringe so that air is purged as shown in the figure below.
Float
GL541-m29E
Needle nose pliers
GL541-m80E
1
2
3
Syringe
Rotary joint
Locking flange
Chapter 3 Changeover
Version 3.6 3-1-2 GL-541E Maintenance
2. Attach the adaptor to the syringe.
3. When necessary, use the centrifugal deairing device (optional) to inject glue into
the adaptor. (Refer to section 4. "Removing Air Bubbles in the Glue".)
4. Mount the needle on the adaptor.
Note: Mount the needle by aligning the adaptor's locating pin with the needle's notch.
5. Push the rotary joint cap all the way to the top end of the syringe, then rotate it
(approximately 90 degrees) until a clicking sound is heard (this locks the cap).
6. Align the adaptor's notch with the syringe holder's pin position, then insert the
syringe assembly into the holder.
Adaptor
Syringe holder
Syringe
Rotary joint
Pin
Notch
GL541-m82E
Notch
Locating pin
GL541-m81E
Adaptor
Needle
Chapter 3 Changeover
Version 3.6 3-1-3 GL-541E Maintenance