8. Install the cap nut. Notes: If a head is not used during production, be sure to install an empty syringe (with adapter attached) and the rotary joint to form an airtight seal. This will prevent air from escaping and h…

100%1 / 32
7. Lift the syringe fixing ring (black) several millimeters, rotate the syringe clockwise
approximately 90 degrees, then return the syringe fixing ring to its original
position to lock the tab.
Note: The syringe fixing ring is held on the head by a magnet.
Note: A syringe or adapter taken from the refrigerator must be allowed to reach room
temperature before use in order to prevent condensation, which can cause the
adapter to rust.
Rust prevents
removal.
GL541-m31Ea
GL541-m83E
Syringe fixing ring
Lock pin
Chapter 3 Changeover
Version 3.6 3-1-4 GL-541E Maintenance
8. Install the cap nut.
Notes:
If a head is not used during production, be sure to install an empty syringe (with
adapter attached) and the rotary joint to form an airtight seal. This will prevent air
from escaping and help to maintain the glue temperature.
After installing the needle and before operation, eject approximately 0.2 cc of glue through
the needle to drive out air trapped in the joint.
The syringes are disposable. Fuji recommends using the syringes twice. Further use will
wear down the ridges which are used to lock the syringe into place and the syringe may fall
from the holder.
<Reference>
Capacity: 30 cc/syringe
Material: Resin (plastic)
Glue volume: Approx. 30 cc.
The syringes are disposable.
The glue must be free of air.
102
1
4
3
2
GL541-m25E
5
(mm)
6
1. Cap (BTRG0870)
2. Cap (BTRG0880)
3. Adhesive (about 30 cc)
4. Syringe (BTRG0750)
5. Float (BTRG0910)
6. Sensor seal (BTRG0900)
Chapter 3 Changeover
Version 3.6 3-1-5 GL-541E Maintenance