4. Remove the needle from the adapter.
Note: Use the jig shown below to remove needles which are stuck to the syringe by dried
glue.
1
4
2
3
1. Holder
2. Retainer
3. Plate
4. Nut
JRG-0700
HRG-1260
JRG-0690
HRG-1271
Jig
Jig Jig
Jig
GL541-m77E
Needle
Adaptor
Chapter 3 Changeover
Version 3.6 3-3-2 GL-541E Maintenance

Installation
1. Remove any hardened glue on the end of the adapter or flange surface of the
needle.
Note: The internal diameter is marked on the needle for identification, as shown in the
following figure.
2. First, mount the adaptor and needle on the syringe, then mount the syringe,
adaptor, and needle assembly on the head's syringe holder.
Note: The mounting orientations of the syringe holder and adaptor, and the adaptor and
needle, are determined by the locating pin and the notch. When setting the needle
in the adaptor and tightening the cap nut, be sure that the adaptor pin is securely
positioned in the needle's notch.
Storage of the Needles
1. Soak nozzles that have been removed in one of the solvents listed below and then
store. To reuse the needle, clean off the solvent and any residual glue using
compressed air.
Solvents: Acetone or trichlene.
“Safety Cleaner 41 g” manufactured by Loctite.
“Cleaner S-10” manufactured by Sanei Chemical Co.
Note: For details, refer to the catalogs of glue manufacturers.
Notch
Locating pin
Needle
Needle
Adaptor
Adaptor
Cap nut
Syringe
holder
GL541-m79E
5
Indicates 0.5 mm inner diameter.
GL541-m38E
Chapter 3 Changeover
Version 3.6 3-3-3 GL-541E Maintenance

Blank Page
Chapter 3 Changeover
Version 3.6 3-3-4 GL-541E Maintenance