SIPLACE Pro V11.2 / Software Version Description Ausgabe 05/2014 Edition
32
TrayStak Feeder AX
– The feeder is only supported on the X4i S placement machine and can be positioned on the
locations 2 and 3 only.
– A table of type "DX Table 40 X" has to be configured. Additionally, the "WPC X" table insert has
to be selected s in order to release the traveling range of the placement head for the feeder.
– Only one Dip module LDU-X can be installed beside the feeder.
– If 2 TrayStak Feeder AX are installed together with an LDU-X, the table has to be manually
selected in the Auto Configuration of the station software.
– No nozzle changer support.
– Stationary camera cannot be used.
– CPP placement head supported only.
– Feeder and placement heads are neither controlled in SIPLACE Pro nor in the station software.
– Due to the hardware, the sequence oft he components (chain) cannot be warranted. Therefore,
setup verification with SIPLACE Setup Center cannot be performed.
– After the machine has been rebooted or the feeder has been locked / unlocked, the feeder has
to be manually activated with the buttons on the feeder each time.
– If the feeder is used without a reject conveyor, this may result in incomplete head cycles what
causes a reduced placement performance.
– If there is no space to put back the component, it will be rejected.
C&P20 M 1xxx placement head
– Supported on the CA-series and the SIPLACE X4 S micron / X4i S micron placement machines
only.
C&P20 P 4xxx placement head
– Supported on the X S-series placement machines only.
Twin VHF 5xx placement head
– Supported on the SX1/SX2 V2 placement machine only.
– No fast gantry exchange possible.
– Must not be used together with the VHF P&P placement head on a machine.
SIPLACE JTF-S
Supported on the SX1/SX2 V2 and the SIPLACE X-series S placement machines only.
SIPLACE JTF-M
– Supported on the SX1/SX2 V2, X4i S micron and the SIPLACE X-series S placement machines
only.
– On the SX1/SX2 V2 placement machine no tape feeder can be placed on the location beside
the JTF-M because no empty tape channel is available.
SIPLACE Pro V11.2 / Software Version Description Ausgabe 05/2014 Edition
33
SIPLACE Wafer Systems
– Supported on the CA-series placement machines only.
– A specific table is required.
Binning can be disabled in SIPLACE Vision
– If binning is disabled in SIPLACE Vision, the measuring in the simulation result of the
optimization will probably take a little longer.
External virtual ink spot handling
– Only possible for stations with station software version => 707.0.
– Physical and virtual ink spot must not be mixed.
– The board must not contain any active ink spots.
CPP / Twin Head placement heads on SIPLACE CA series
– Stationary cameras may be installed on location 1 and 3 only.
– Twin Head may be installed on location 3 only.
– The CPP placement head is only supported in the high position on SIPLACE Wafer Systems.
Restrictions in the Production Scedule
PCB barcode mode is not supported.
Spring placement process
The board top edge position has to be constant from board to board to allow absolute placement.
Variable board warpages cannot be compensated.
SIPLACE Pro V11.2 / Software Version Description Ausgabe 05/2014 Edition
34
6 Troubleshooting
Error Reporting Tool
The Error Reporting Tool allows you to transfer detailed information about any errors occurring in
SIPLACE Pro to the service team. For more information about this function, refer to section 8.1
SIPLACE Net Error Reporter Service, the Online Help or the Support Media DVD.
Error Reports with the SIPLACE Net Error Reporter Service
The SIPLACE Net Error Reporter Service can be started as follows:
– Via Start – Programs – SIPLACE Net – Enterprise Service – SIPLACE Net Error Reporter
Service
– Via the Strg+Alt+F10 key combination.
– Via Help – Error Reporting in the menu of the GUIs.
Follow the instructions on the screen.
6.1 Problems and Solutions
This section describes known circumstances and general problems. If applicable, troubleshooting
is provided to help you working with SIPLACE Pro.
Solving Problems in Workgroup Mode
If you operate SIPLACE Pro in workgroup mode and if e. g. during the startup of the SIPLACE Pro
LineControl GUI application a message is displayed stating that:
It was not possible to establish a connection to the SIPLACE Pro
Interface. The cause for the error was: Unknown error (0x80004005).
► Check, if the following password requirements are met:
– The local user data must also be set up on the workgroup server.
– The local user must have the same password as on the workgroup server.