00196624-04_Service Manual WPC5_6_EN_01-2019.pdf - 第18页

Service Manua l WPC5 / WPC6  Page 3- 18 3.4 Drive Unit – Feed Axis 3.4.1 Preparations Tools Required • W ater pump pliers • Standard tool with set of Allen wrenches • Setting gauge, large, f or crash light barrier [03 0…

100%1 / 143
Service Manual WPC5 / WPC6
Page 3-17
Removal / Installation
The drive motor (1) of the lifting axis is located behind the front cover. If the drive motor is
disconnected from the power supply, the drive is fixed with a brake.
Loosen the two motor support fastening screws (2) sealed with locking varnish.
Loosen (do not remove) the tensioning screw (5) on the tensioning device. This relaxes the
drive toothed belt.
Loosen and remove the 2 fastening screws (2) and then remove the toothed belt (3).
Loosely fix the motor support and drive motor into the installation position, with the 2
fastening screws (2).
Run the new drive toothed belt around the two toothed wheels and tension (pretension) the
toothed belt at the slot provided, with the help of the motor support.
Set the final belt tension. To do this, tension the drive toothed belt at the tensioning device,
with the help of the tensioning screw (5). This moves the motor support accordingly in the
slots.
Setting value: Set the belt tension to 235 Hz.+/- 10 Hz.
Tighten the 2 fastening screws (2) on the motor support, check the belt tension and adjust
where necessary.
Seal the 2 fastening screws (2) with locking varnish.
Calibrate the lifting axis.
Service Manual WPC5 / WPC6
Page 3-18
3.4 Drive Unit – Feed Axis
3.4.1 Preparations
Tools Required
Water pump pliers
Standard tool with set of Allen wrenches
Setting gauge, large, for crash light barrier [03051814-01]
Setting gauge, small [03052363-02]
Belt tension measuring device [00326015-01] with instruction guide
Prerequisite
Move the tower into the refill position.
Remove all waffle pack tray carriers (WPTCs) from the tower.
Move the tower downwards.
Check sensors and functions ⇨ Check sensors and functions of specific components ⇨ Location ⇨
Check functions for WPC ⇨ Move into transport position
Switch the WPC off at the main switch.
Unplug from the power supply and secure the WPC to prevent unauthorized reactivation.
Undock the WPC from the SIPLACE machine and move it to a suitable position for service
work.
Remove the jumper cover.
Remove the feed axis cover.
Overview
(1) Feed axis cover
(2) Bridge cover (hand guard on
tower)
(3) Feed axis drive motor
(4) Toothed belt for the drive
(5) Feed axis toothed belt
Service Manual WPC5 / WPC6
Page 3-19
3.4.2 Replace the Feed Axis Drive Motor
Spare Part:
When replacing the drive motors of the WPC5 and WPC 6, it is, with immediate effect,
necessary to take note of the version / item number of the motor, as the successors are not
100% compatible.
Because it is not permitted to install a mixture of new motors in a WPC, the old drives continue
to be available as replacements!
As a result of this incompatibility, the version of the entire WPC was changed when the new
drives were introduced.
Overview
(1) Feed axis motor, compl.
(2) Tensioning screw
(3) 2 x motor support fastening
screws
(4) Toothed belt for the drive
(5) Deflection pulley
(6) 4 x drive motor fastening screws
(7) Electrical connections
WPC Type / Version
Spare Part Name
Part No.
„WPC5 900-950mm / Standard“
[03067619-
03]
"Servo motor 1FK7022-5AK71-
1AH3-Z S52"
[03159574-xx]
„WPC6 900-950mm“
[03067618-
03]
„WPC5 900-950mm / Standard“
[03067619-
04]
Servo motor 1FK7022-5AK74-
1AH3-Z + S52
[03161141-xx]
„WPC6 900-950mm“
[03067618-
04]