44 cab - Produkttechnik GmbH / Tharo Systems, Inc. System Mode SYSTEM TEST When switched on, the Apollo automatically performs an internal self test. If the test is completed successfully , the Apollo proceeds to the ONL…

43cab - Produkttechnik GmbH / Tharo Systems, Inc.
System Mode FAULT-IRRECOVERABLE
While switching on the printer or during printing, a fault has occured which
cannot be cleared by the operator without cancelling the current print run. (e.g.
hardware fault)
Display
The display shows the type of fault.
LED Display
LED CAN is flashing.
Function Keys
CAN key Cancels the current print job.
Switch into ONLINE mode.
(LED ONL on, LED CAN off, LED PSE off)
If ONLINE mode cannot be entered, switch printer on and off
again.
If the fault remains contact Technical Service.
Table 8 f Function keys in mode FAULT - IRRECOVERABLE

44 cab - Produkttechnik GmbH / Tharo Systems, Inc.
System Mode SYSTEM TEST
When switched on, the Apollo automatically performs an internal self test.
If the test is completed successfully, the Apollo proceeds to the ONLINE mode,
or otherwise the printer switches to system mode FAULT - IRRECOVERABLE.
Display
The top line of the display shows the version of the printer, for instance
" **** APOLLO 3 **** ".
The bottom line of the display shows the numbers "123456" one after the other
depending on the progress of the several test steps.
LED Display
All LEDs flash up once briefly.
Function keys
The function keys have no effect.

45cab - Produkttechnik GmbH / Tharo Systems, Inc.
System Mode SETUP
To enter the SETUP mode, use either one of the procedures described below :
either : press both keys, the key and the key
simultaneously when switching on the printer, and keep them
pressed down, until the system test is completed;
or : in ONLINE mode, press both keys, the key and the
key simultaneously for at least 5 seconds.
In SETUP mode, various printer parameters can be specified to suit the current
print requirements. (for details see Chapter 9)
Display
Following the completion of the system test, the display briefly shows "SET-
UP", followed by "Land" or "Country". Depending on the selection, all of the
setup parameters and their settings will be shown.
LED Display
All LEDs off.
Function Keys
ONL key Stores the chosen settings of the setup parameters and
completes the SETUP mode.
(i.e. switch into ONLINE mode/ LED ONL on)
FF key Skips to next setup parameter.
Reduces numerical setup values.
CAN key Skips to previous setup parameter.
Increases numerical setup values.
PSE key Confirms selected settings for parameters.
Table 8 g Function keys in SETUP mode