Apollo1_Operators_Manuel.pdf - 第59页

59 cab - Produkttechnik GmbH / Tharo Systems, Inc. Heat Level The parameter "Heat level" enables the printer to adapt to possible differences in the thermal properties of different printheads. The parameter sca…

100%1 / 133
58 cab - Produkttechnik GmbH / Tharo Systems, Inc.
Printhead Position
The "Printhead position" parameter defines the location of the print image on
the label.
The parameter should especially be altered if you are using the same label
formats on several printers, and you find the print image located differently on
the labels when they were printed on another printer. (range from -.33 to +.33
in or -8.4 mm to +8.4 mm)
If the printhead position value is positive, the print image is shifted further to
the rear edge of the label.
Adjustments for various print jobs may also be carried out via software which
provides an additional offset value.
You may also change this value using the software commands. Any front panel
value and software command value are totaled together for printing.
The current field to be changed is flashing.
6 Peel position
8 Heat level
7 Printhead pos.
Printhead pos.
+ x.x mm
Printhead pos.
- x.x mm
Printhead pos.
± 9.x mm
Printhead pos.
± 0.x mm
Printhead pos.
± x.9 mm
Printhead pos.
± x.0 mm
*
*
*
*
*
*
Printhead pos.
± x.x mm Yes
Printhead pos.
± x.x mm No
Confirmation
Sign (+ or -)
1/10 mm
mm
Fig. 9 h Set "Printhead position" parameter
F
59cab - Produkttechnik GmbH / Tharo Systems, Inc.
Heat Level
The parameter "Heat level" enables the printer to adapt to possible differences
in the thermal properties of different printheads.
The parameter scale is from -9 to +9.
A previous adjustment has already been carried out in the factory.
In the event of replacing the printhead, the setting possibly has to be adjusted.
To adjust the printer to current print jobs, it is recommended that you alter the heat
level parameter via software. (e.g. for different material and speed)
You may also change this value using the software commands. Any front panel
value and software command value are totaled together for printing.
The current field to be changed is flashing in the display.
Fig. 9 i Set "Heat level" parameter
Heat level
+ x
Heat level
- x
Heat level
± 9
Heat level
± 0
*
*
*
Heat level
± x Yes
Heat level
± x No
Confirmation
Sign (+ or -)
8 Heat level
9 Printer info
Heat level
7 Printhead pos.
F
60 cab - Produkttechnik GmbH / Tharo Systems, Inc.
Printer Info
The "Printer info" parameter provides information about the firmware.
Furthermore, information about the cumulative length of printed media as well
as the number of operating hours are shown.
8 Heat level
9 Printer info
10 Set date
Printer info
Printer info
Version xxxxxxx
Printer info
xxxxxx m/ xxxx h
Fig. 9 k Printer info display