HS Preventive Maintenance 4 W eekly maintenance jobs 01/2006 US Edition 25 Check th e filter mats of the air filter box (Option) 4 : Check the filte r mats in the air fil ter boxe s for dirt. For ligh t to ave rage so il…

100%1 / 86
4 Weekly maintenance jobs HS Preventive Maintenance
01/2006 US Edition
24
4
HS Preventive Maintenance 4 Weekly maintenance jobs
01/2006 US Edition
25
Check the filter mats of the air filter box (Option) 4
: Check the filter mats in the air filter boxes for dirt.
For light to average soiling, clean the filter mats with the vacuum cleaner.
Replace the filter mats if they are very dirty.
4
4
Clean the X/Y scales (if required) 4
4
Only use soft cloths to clean the scale rods. Do not apply too much pressure. 4
4
a Clean the incremental scales of the X and Y axes, if required using a lint-free soft cloth moist-
ened with ethyl alcohol.
4
Dirty scale rods lead to counting errors on the X and Y axes, and thus result in machine stoppages.4
4
4
4
Change the nozzle changer magazines 4
: Use the "Single Functions" menu to return the nozzles of the Collect&Place head to the nozzle
changers.
s Remove the nozzle changer magazines and replace them with magazines with cleaned ce-
ramic nozzles or new nozzles.
: Use the "Single Functions" menu to pick up the nozzles of the Collect&Place head once more.
4
4
: Empty the nozzle reject bin.
: Repeat the job at the other locations.
4
4
4 Weekly maintenance jobs HS Preventive Maintenance
01/2006 US Edition
26
4