Retrofit instructions: New 1-wire wiring for the SIPLACE X-series 11/2005 Edition 50 : Remove the complete gray cable from conn ector X1*2 with all the wires (5x). (See retrofit instructions: "Mod ification of the p…

Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
49
: Connect the long cable to the short cable and pull the other end into the middle of the machine
frame.
2
2
2
2
2
2
2
2
2
2
2
2
2
Running the cables

Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
50
: Remove the complete gray cable from connector X1*2 with all the wires (5x).
(See retrofit instructions: "Modification of the power supply to the DLM nozzle changer, SI-
PLACE HF series", item no.: 00194610-xx)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Remove cable X1*2.
Use the Phoenix connector for the splitter.

Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
51
: Use the green connector to connect the long 24V cable to the 1-wire CAT5 splitter.
Connection to the connector:
2
2
This completes the conversion of the 24V supply to the nozzle changer on the sub-distributor. 2
: Now convert the 24V supply on the main distributor as well.
PIN 1 Brown: 24V
PIN 2 White: Ground
Connection for location 1/2
Connection for location 3/4
1-wire CAT5 splitter