Retrofit instructions: New 1-wire wiring for the SIPLACE X-series 11/2005 Edition 71 2.9.2 Fitting the new variant 2 : Download the E01 10350.bhx app lication to th e I/O modules. 2 2.9.2.1 1-wire bridge 2 Fig. 2.9 - 10 …

100%1 / 82
Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
70
Fig. 2.9 - 7 NC control board, on the 20 C&P head only
Fig. 2.9 - 8 Position of the temperature sensors on the head assembly board
Fig. 2.9 - 9 Temperature sensors / Gantry identification
2
2
The temperature sensors are connected directly to the head board X20 or X21 (head interface
C500). It does not matter which connectors are used to connect the individual temperature sen-
sors. 2
Display (2 LEDs) for NC - C&P20 (cannot be seen through the cover beneath the NC)
Light barrier for NC open/closed and NC valve open/closed
(1) Temperature sensor on the PCB camera (2) Temperature sensor / Gantry identification
(1) Temperature sensor on the PCB camera (2) Temperature sensor / Gantry identification
5
Connection to the
1-wire hub, NC
1
2
6
Assembly side of placement head
6
2
1
Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
71
2.9.2 Fitting the new variant
2
: Download the E0110350.bhx application to the I/O modules.
2
2.9.2.1 1-wire bridge
2
Fig. 2.9 - 10 1-wire bridge
: Replace the 1-wire bridge, material number 03010576-03, in the sub and main distributor with
the 1-wire bridge, material number 03041578-01.
: Connect the CAT5 cable to the 1-wire CAT5 socket and the CAN sub-D cable
(see Fig. 2.9 - 11).
: Set the MA/PC switch to MA for machine mode.
The V2/V3 switch must always be set to V2 (see picture above).
2
Fig. 2.9 - 11 1-wire bridge plugged into the I/O module
Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
72
2.9.2.2 1-wire CAT5 splitter
2
Fig. 2.9 - 12 1-wire CAT5 splitter
2
: Fit two 1-wire CAT5 splitters in the machine - one per placement area.
: Place the 1-wire CAT5 splitter in the right-hand recess of the machine frame.
: Connect the CAT5 cable for the nozzle changers and temperature sensors and the 1-wire
bridge to the 1-wire CAT5 splitter (mat no.: 03040219-01) (see photograph on next page).
The splitter is also powered by a 24 V cable.
Individually: 2
PA1:
To X4 CAT5 cable for NC, gantry 1
To X3 CAT5 cable for temperature sensors, gantry 1 and 4
To X4 CAT5 cable for NC, gantry 4
To X1 24 V cable from sub-distributer
To X5 CAT5 cable from the 1-wire bridge on the sub-distributer
PA2:
To X4 CAT5 cable for NC, gantry 2
To X3 CAT5 cable for temperature sensors, gantry 2 and 3
To X4 CAT5 cable for NC, gantry 3
To X1 24 V cable from main distributor
To X5 CAT5 cable from the 1-wire bridge on the main distributor
1-wire CAT5 splitter
Connection for location 1/2
Connection for location 3/4