Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
50
: Remove the complete gray cable from connector X1*2 with all the wires (5x).
(See retrofit instructions: "Modification of the power supply to the DLM nozzle changer, SI-
PLACE HF series", item no.: 00194610-xx)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Remove cable X1*2.
Use the Phoenix connector for the splitter.
Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
51
: Use the green connector to connect the long 24V cable to the 1-wire CAT5 splitter.
Connection to the connector:
2
2
This completes the conversion of the 24V supply to the nozzle changer on the sub-distributor. 2
: Now convert the 24V supply on the main distributor as well.
PIN 1 Brown: 24V
PIN 2 White: Ground
Connection for location 1/2
Connection for location 3/4
1-wire CAT5 splitter
Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
52
2.8 Variant 1
2
: Download the E0110350.bhx application to the I/O modules.
2
2.8.1 CAN bus cable at RS232 bridge
: Remove the CAN bus cable from the RS232 bridge.
: Connect the additional CAN bus cable between the RS 232 bridge and interface for the 1-wire
CAT5.
: Connect the green CAT5 cable to the converter and pull it into the middle of the machine frame.
2
Connections for the CAT5 converter
MA CAN bus
RS 232 interface