2OM-1086-002.pdf - 第104页

0211-005 Chapter 1 2 - 39 Tg0583-PM-D2 2.4 “PCB Backup” T ab * 4 V acuum Rel. Wait Time [sec] Make the ten-key window appear and enter a value in the text box. The value can be changed only when "V acuum Plate"…

100%1 / 455
2.4 “PCB Backup” Tab
*1
*2
*7
*6
*4
*5
*3
0211-005 Chapter 1 2-38 Tg0583-PM-D2
2.4 "PCB Backup" Tab
The corresponding tab sheet can be used to specify how to support a
P.C.B., etc.
• Sheet Layout
When you push the "PCB Backup" tab in the "Pattern Program" edit
window, the following tab sheet appears.
Fig. 3B88 "PCB Backup" Tab Sheet
• Sheet Composition
*1 Chuck Stage Select
Push the text box twice. The text box changes to a combo box.
Push the down arrow to open the drop-down list. Select "Backup
Jig", "Backup Pin", or "Vacuum Plate" from the drop-down list.
*2 PCB Warpage Protection
Push the text box twice. The text box changes to a combo box.
Push the down arrow to open the drop-down list. Select "OFF" or
"ON" from the drop-down list.
*3 Vacuum Release Mode
Push the text box twice. The text box changes to a combo box.
Push the down arrow to open the drop-down list. Select "Before" or
"After" from the drop-down list.
The value can be changed only when "Vacuum Plate" is
selected in the "Chuck Stage Select" text box *1.
0211-005 Chapter 1 2-39 Tg0583-PM-D2
2.4 “PCB Backup” Tab
*4 Vacuum Rel. Wait Time [sec]
Make the ten-key window appear and enter a value in the text box.
The value can be changed only when "Vacuum Plate" is selected
in the "Chuck Stage Select" text box *1.
*5 PCB Clamp Offset
Timing [sec] : Make the tenkey window appear and
enter a value in the text box.
Position [mm] : Make the tenkey window appear and
enter a value in the text box.
Bef.Clamp Bkup Spd. : The ascending speed of the backup
table can be set in the range of 10 steps
(Full Speed to 90% Down) before the
P.C.B. is clamped.
Aft.Clamp Bkup Spd. : The ascending speed of the backup
table can be set in the range of 10 steps
(Full Speed to 90% Down) after the
P.C.B. is clamped.
*6 PCB Stopper Offset Y [mm]
Make the ten-key window appear and enter a value in the text box.
*7 PCB Cut Offset [mm]
Make the ten-key window appear and enter a parameter in the text
box.
2.5 "PEC Recog" Tab
• Sheet Layout
When you push the "PEC Recog" tab in the "Pattern Program" edit
window, the following tab sheet appears.
Fig. 3B89 "PEC Recog" Tab Sheet
• Sheet Composition
*1 P.E.C. Recog. Function
Push the text box twice. The text box changes to a combo box.
Push the down arrow to open the drop-down list. Select "2PT."
from the drop-down list.
The drop-down list has rows of options - "OFF", "1PT.",
"2PT.", and "3PT.". However, be sure to select only "2PT.".
*2 Center Recognition
Push the text box twice. The text box changes to a combo box.
Push the down arrow to open the drop-down list. Select "OFF" or
"ON" from the drop-down list.
*3 Fiducial Mark #1
Display the ten-key window and input the values for X (width), Y
(length), Code Gain (only when the automatic gain adjustment is
not used) and Level (only when the automatic gain adjustment is
not used).
2.5 “PEC Recog” Tab
0211-005 Chapter 1 2-40 Tg0583-PM-D2
*1
*2
*3
*4
*5
*6