12.1 Replenishment of Cleaning Solvent 0509-006 Chapter 3 1 - 42 Tg0583-PM-D2 (3) Remove the cap and the internal lid of the solvent tank. Fig. 5A54 Fig. 5A54 Fig. 5A54 Fig. 5A54 Fig. 5A54 (4) Replenish the solvent tank …

12.1 Replenishment of Cleaning Solvent
• Use industrial alcohol as a cleaning solvent for this machine.
Refer to "2.1 Preparation for Cleaning Tools" for the kinds of
industrial alcohol.
Work Procedure
(1) Shut down the power to the machine.
Fig. 5A52
(2) Open the safety doors on the rear side.
Fig. 5A53
12.1 Replenishment of Cleaning Solvent
0509-006 Chapter 3 1-41 Tg0583-PM-D2
Industrial alcohol supply must be replenished with the power switch
of the machine being turned "OFF".
Only the person in charge of maintenance work should perform this
operation.
CAUTION
ON
tripped
reset
OFF
0
p
u
s
h
to
trip
Safety Door
Safety Doo
r

12.1 Replenishment of Cleaning Solvent
0509-006 Chapter 3 1-42 Tg0583-PM-D2
(3) Remove the cap and the internal lid of the solvent tank.
Fig. 5A54Fig. 5A54
Fig. 5A54Fig. 5A54
Fig. 5A54
(4) Replenish the solvent tank with additional industrial alcohol, using the
replenishment container.
To avoid solvent drips, be sure to use the replenishment
container equipped with a nozzle.
If you spill solvent by mistake, clean it up with a rag as soon
as possible.
After cleaning up the spilt solvent, confirm that it has dried
completely and enough ventilation is provided. After that, turn
on the power switch of the machine.
Fig. 5A54-1Fig. 5A54-1
Fig. 5A54-1Fig. 5A54-1
Fig. 5A54-1
Cap
Internal Lid
Notice

12.1 Replenishment of Cleaning Solvent
0509-001 Chapter 3 1-42-1 Tg0583-PM-D2
• The solvent tank must be filled up to the "MAX" line with industrial
alcohol. (Approx. 1,500 ml or less)
If you fill the tank beyond the "Max" line, alcohol will overflow and drip
out of the tank, down to the floor.
Fig. 5A54-2 Solvent Tank
(5) After the replenishment of industrial alcohol, attach the internal lid of
the solvent tank and tighten the cap securely.
If air gets into the tube running between the solvent tank and the
discharge nozzle, industrial alcohol may not come out soon.
In this case, discharge a little amount of alcohol to let the air escape,
using the [Dispense Solvent (ON-OFF)] switch on the rear operation
panel.
Fig. 5A54-3
Solvent
Internal Lid
Cap
Gasket
Joint
Leeway
MAX Line
[Dispense Solvent (ON-OFF)] Switch
Note