2OM-1086-002.pdf - 第331页
9. 2 Replacement Procedure of Blower Filter Operation Procedure (1) Remove the cover located at the lower part of the rear side. (4 screws) Fig. 5A37-6 (2) Disengage the clip fastening the lid of the filter cover . (4 pl…

9.1.1 Adjustment of Squeegee Head Height
••
••
• Rubber Squeegees
Adjustment Procedure
(1) Loosen the wing and stopper nuts.
Fig. 5A37-1
(2) Adjust the pushing distance by changing Dimension L (the dis-
tance between the upper end plane of the ball bushing and the
lower end plane of the stopper nut).
The pushing distance of the squeegee against the screen is set
to "1.0 mm". (Factory-Adjusted upon Shipment)
When the stopper nut is turned once clockwise, the pushing
distance becomes shorter by 1.0 mm.
Turning the stopper nut once counterclockwise makes the push-
ing distance longer by 1.0 mm.
Ref.:
Pushing Distances Dimension L during Upward
Movement of Cylinder
0.5 mm 57.5 (58.5) mm
1.0 mm 57.5 (59.0) mm (Standard Setting)
1.5 mm 58.0 (59.5) mm
The values in ( ) are applied when metal squeegees are used.
Permalex : Type No. PLX-A3060-270
PLX-A3060-350
(3) Open the "SEMI-AUTO OPN." window (submenu) or the "Print
Block" tab sheet of the "MAN. SUB-SYS" window (submenu)
and push the squeegee against the P.C.B. located in the print-
ing section.
Refer to the above table and check the relation between Di-
mension L and the pushing distances.
0211-005 Chapter 3 1-31-1 Tg0583-PM-D2
9.1 Replacement of Squeegees
Stopper Nut
Wing Nut
L

9.2 Replacement Procedure of Blower Filter
Operation Procedure
(1) Remove the cover located at the lower part of the rear side.
(4 screws)
Fig. 5A37-6
(2) Disengage the clip fastening the lid of the filter cover.
(4 places)
Fig. 5A37-7
(3) Remove the lid.
Fig. 5A37-8
9.2 Replacement Procedure of Blower Filter
Clip
0211-005 Chapter 3 1-31-2 Tg0583-PM-D2
Cover

(4) Detach the filter and remove dust accumulated on the filter with an
air gun and a vacuum cleaner.
Fig. 5A37-9
(5) Set the filter such that the center hole of the filter can fit into the
flange located at the rear side of the filter cover.
Fig. 5A37-10
(6) While holding the lid, engage the clip securely such that the flange
(located at the center of the lid) can fit into the center hole of the
filter.
Fig. 5A37-11
9.2 Replacement Procedure of Blower Filter
0211-005 Chapter 3 1-31-3 Tg0583-PM-D2
Flange Section
Flange Section