2.10.2 Illumination Check
NOTE:
We recommend that you conduct the illumination check be performed after the PCB camera Mul-
ticolor is assemblied, reinstalled or exchanged. By appropriately switching over the vision screen
(see User Manual) it is possible to precisely check the function of the pertinent light level and, for
example, the change from full to one-half brightness. 2
2
: In the SITEST program 502.xx select the ICON "Gantries" and then the "Gantry 1" .
: Click on the CON "PCB camera functions" .
The following screen is displayed (using S-25 HM as an example):
Fig. 2.10.2 Menu "Setting of Illumination" for PCB Camera"
2
2
2

SIPLACE S-25 HM / S-27 HM 2 Assembly Instructions for PCB Camera, Multicolor
02/2007 Edition 2.4 SITEST: Configuration and Illumination Check of all PCB Cameras Multicolor
81
: Click on the button "Illumination values for live image".
In principle, you can use this function to test whether the illumination of the PCB camera Mul-
ticolor is activated. The illumination levels "White" and "Blue" are visible; "IR" is not.
: The screen "Illumination values for live image" is displayed:
Fig. 2.10.3 Screen: "Illumination Values for Live Image"
: If the Multicolor camera(s) was (were) assemblied, reinstalled or exchanged, you must test at
least the illumination levels "White" and "Blue" because their light is visible.
: Click on the "Radio button" to select the illumination level "White".
: Deactivate the button "Reduced brightness" and click on the button "Accept".
The complete illumination level is therefore activated at the outset.
: Switch to the menu "Teach PCB camera" -> Click on the button "PCB camera":
Make a visual check (with safety hoods closed):
The camera’s white light must flash.
: Once again, press the button "Illumination values for live image".
: Now activate the option "Reduce illumination".
This reduces the illumination level by one-half.

2 Assembly Instructions for PCB Camera, Multicolor SIPLACE S-25 HM / S-27 HM
2.4 SITEST: Configuration and Illumination Check of all PCB Cameras Multicolor 02/2007 Edition
82
: Click on the button "Accept" again.
: Make a visual check (with the safety hoods closed):
The camera’s white light must flash repeatedly but not as brightly as before.
: Execute the above-described check for illumination level "blue" as well.
: Exit the menu "(Gantry 1) PCB camera".
: In the menu "PCB functions" select the button "PCB camera" of gantry 2.
One after the other, perform the above-described operation for these PCB cameras Multicolor.
NOTE:
If you would like to check the IR illumination levels too, perform the above-described operation in
a like manner for these levels also and. Place a white sheet of paper under the camera. As a
check, switch over to the vision screen in each case. 2
: Afterward, test to make certain that the camera illumination goes OFF in response to safety
shutoff, as described in Abschn. 2.11.