3.1.6 Noise Measurement
Here is the noise data of the machine measured at each point as shown below.
Measured Points
Noise Data
Point A B C D E F G H I J K L M N O P
Measured
value
(dB (A))
71.2 71.8 73.5 72.4 72.2 70.1 70.3 71.4 72.8 72.6 70.7 69.9 70.9 71.4 71.7 71.2
Dark noise: 43.3 dB (A)
(Plane view) (Side view)
AV131
MAINTENANCE MANUAL
3.1 Outline of Installation
D79MEC-11-010-A0
3.1-5
3.1.7 Connecting the Air Supply
Connect the primary air piping to the machine.
Make sure that the primary air pressure is more than 0.5MPa and the flowrate more than 150L/min (A.N.R).
=REMARKS=
The primary air shall have no foreign substance such as moisture.
After completing the piping connection, supply the primary air, and adjust it to 0.5 MPa using the MR unit.