109 E601014 “Axis Driver: Failed amp enable. (ZT3)” [Cause] An internal error in the system. T he servo am plif ier cannot be enabled. The X MP board or system HDD m ay have failed. [Treatm ent] Exit the system. Contac t…

100%1 / 1361
108
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E600036 “Axis Driver: The velocity error exceeded the limit. (Check the
power supply for the possibilities of low power supply voltage.)”
[Cause]
An error occurred in the servo system.
Fluctuations in the driving power may have prevented the proper operation of the system.
[Treatment]
Check the conditions of the machine power source.
E600040 “Out of the movable range.”
[Cause]
The destination coordinates of the axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate within the movable range.
E601001 “Axis Driver: Failed servo power on.”
[Cause]
Could not turn ON the servo power.
The possible cause is; detection by the limit sensor or area sensor, pressing of the emergency
stop switch, or the power OFF state (of the safety type machine).
Also there may be wrong or poor electrical connections.
[Treatment]
Remove the cause and return the axes to the home position.
E601010 “Axis Driver: Failed amp enable. (XY)”
[Cause]
An internal error in the system. The servo amplifier cannot be enabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601011 “Axis Driver: Failed amp enable. (YC)”
[Cause]
An internal error in the system. The servo amplifier cannot be enabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601012 “Axis Driver: Failed amp enable. (ZT1)”
[Cause]
An internal error in the system. The servo amplifier cannot be enabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601013 “Axis Driver: Failed amp enable. (ZT2)”
[Cause]
An internal error in the system. The servo amplifier cannot be enabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
109
E601014 “Axis Driver: Failed amp enable. (ZT3)”
[Cause]
An internal error in the system. The servo amplifier cannot be enabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601015 “Axis Driver: Failed amp enable. (ZT4)”
[Cause]
An internal error in the system. The servo amplifier cannot be enabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601020 “Axis Driver: Failed amp disable. (XY)”
[Cause]
An internal error in the system. The servo amplifier cannot be disabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601021 “Axis Driver: Failed amp disable. (Yc)
[Cause]
An internal error in the system. The servo amplifier cannot be disabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601022 “Axis Driver: Failed amp disable. (ZT1)”
[Cause]
An internal error in the system. The servo amplifier cannot be disabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601023 “Axis Driver: Failed amp disable. (ZT2)”
[Cause]
An internal error in the system. The servo amplifier cannot be disabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601024 “Axis Driver: Failed amp disable. (ZT3)”
[Cause]
An internal error in the system. The servo amplifier cannot be disabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601025 “Axis Driver: Failed amp disable. (ZT4)”
[Cause]
An internal error in the system. The servo amplifier cannot be disabled.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601030 “Axis Driver: Failed alarm clear. (XY)
[Cause]
An internal error in the system. The system fails to clear the alarm.
110
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601031 “Axis Driver: Failed alarm clear. (Yc)”
[Cause]
An internal error in the system. The system fails to clear the alarm.
The XMP board or system HDD might go wrong.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601032 “Axis Driver: Failed alarm clear. (ZT1)”
[Cause]
An internal error in the system. The system fails to clear the alarm.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601033 “Axis Driver: Failed alarm clear. (ZT2)”
[Cause]
An internal error in the system. The system fails to clear the alarm.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601034 “Axis Driver: Failed alarm clear. (ZT3)”
[Cause]
An internal error in the system. The system fails to clear the alarm.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601035 “Axis Driver: Failed alarm clear. (ZT4)”
[Cause]
An internal error in the system. The system fails to clear the alarm.
The XMP board or system HDD may have failed.
[Treatment]
Exit the system. Contact our service engineer or the agency.
E601040 “Axis Driver: Failed CAL.BLOCK mark Recognition. (L-OCC)”
[Cause]
Failed to recognize the CAL block first mark. Possible causes are as follows:
1. The mark is shielded.
2. The CAL block light cannot light up.
3. The OCC cannot move over to the mark position.
4. The cable or connection with the OCC has gone wrong.
5. The image processing board has gone wrong.
[Treatment]
Check the machine conditions and return the axes to the home position.
If the error persists, exit the system and contact our service engineer or the agency.
E601041 “Axis Driver: Failed CAL.BLOCK mark Recognition. (R-OCC)”
[Cause]
Failed to recognize the CAL block first mark. Possible causes are as follows:
1. The mark is shielded.
2. The CAL block light cannot light up.
3. The OCC cannot move over to the mark position.
4. The cable or connection with the OCC has gone wrong.
5. The image processing board has gone wrong.