4OM-1842-005_G5S_Vol4.pdf - 第277页
3.13 Apprendimento automatico Error ID Error Name, Description, Cause, and Remedy 600903 T eaching Leaning Nozzle offset Error of coordinates calculation. ----- 600904 T eaching Leaning Nozzle offset Error of Data set fo…

3.13 Apprendimento automatico
Error ID Error Name, Description, Cause, and Remedy
600707 Fly recog. Offset teach
Error of moving for XY Beam.
-----
600708 Fly recog. Offset teach
Time-out in XY Beam movement
-----
600709 Fly recog. Offset teach
Time-out of communication with recognition
-----
600801 Teaching Pick-up Position
Please push the Feeder Ready SW
-----
600802 Teaching Pick-up Position
Error of Feeder Mark Recognition
-----
600803 Teaching Pick-up Position
Feeder connection is set in test mode.
Please set test pattern "OK"
600804 Teaching Pick-up Position
The data of the feeder was not able to be read.
Please exchange Feeder
600805 Teaching Pick-up Position
Time-over of Feeder Mark Recognition Process
-----
600806 Teaching Pick-up Position
Time-out in XY Beam movement
-----
600807 Teaching Pick-up Position
Error of moving for XY Beam.
-----
600808 Teaching Pick-up Position
Error of processing Recognition Stop
-----
600809 Teaching Pick-up Position
Error of processing Light on
-----
60080a Teaching Pick-up Position
Error of processing image capture
-----
600901 Teaching Leaning Nozzle offset
Could not recognize Glass Jig
Please conrm that Glass Jig is set on Glass Jig place.(Check it because there is
a possibility that nozzle is not on head, or vacuum is not "ON".)
600902 Teaching Leaning Nozzle offset
Error of Recognition Command Response
-----
4OM-1842
3-1421701-005

3.13 Apprendimento automatico
Error ID Error Name, Description, Cause, and Remedy
600903 Teaching Leaning Nozzle offset
Error of coordinates calculation.
-----
600904 Teaching Leaning Nozzle offset
Error of Data set for XY Beam.
-----
600905 Teaching Leaning Nozzle offset
Error of moving for XY Beam.
-----
600906 Teaching Leaning Nozzle offset
Time-out in XY Beam movement
-----
600907 Teaching Leaning Nozzle offset
Time-out of communication with recognition.
-----
600908 Teaching Leaning Nozzle offset
Error of Leaning Nozzle offset teaching
-----
600909 Teaching Leaning Nozzle offset
Error of Noz Select Axis Pos. Offset Teaching
-----
60090A Teaching Leaning Nozzle offset
Noz Select Axis Pos. Offset is out of permission values.
There is a possibility that Head Rotate Theta Axis offset is not correct. / There is
a possibility that Light Emitter and Receiver of Linear measuring Sensor has aw
and soil / There is a possibility that Nozzle is damaged. / There is a possibility that
Head has some problem.
60090B Teaching Leaning Nozzle offset
Could not measure correctly on Noz Select Axis Pos. Offset Teaching.
There is a possibility that Head Rotate Theta Axis offset is not correct. / There is
a possibility that Light Emitter and Receiver of Linear measuring Sensor has aw
and soil / There is a possibility that Nozzle is damaged. / There is a possibility that
Head has some problem.
601001 Master nozzle level offset teach
Error is detected before Line Sensor measurement began
-----
601002 Master nozzle level offset teach
Error of NS-axis movement
-----
601003 Master nozzle level offset teach
Error of DD-axis movement
-----
601004 Master nozzle level offset teach
Time-out of NS-axis movement
-----
4OM-1842
3-1431701-005

3.13 Apprendimento automatico
Error ID Error Name, Description, Cause, and Remedy
601005 Master nozzle level offset teach
Time-out of DD-axis movement
-----
601006 Master nozzle level offset teach
Time-out when Line Sensor measurement began
-----
601007 Master nozzle level offset teach
Read Time-out of Line Sensor measurement
-----
601101 Noz level offset teaching
Time-out when Line Sensor measurement began
-----
601102 Noz level offset teaching
Read Time-out of Line Sensor measurement
-----
601103 Noz level offset teaching
Error during Line Sensor measurement
-----
601104 Noz level offset teaching
Error of dirty Line Sensor
-----
601105 Noz level offset teaching
Error of NS-axis Origin calculation
-----
601106 Noz level offset teaching
Error of NS-axis movement
-----
601107 Noz level offset teaching
Error of DD-axis Origin Calculation
-----
601108 Noz level offset teaching
Error of DD-axis movement
-----
601109 Noz level offset teaching
Program Error
-----
60110a Noz level offset teaching
Error before Line Sensor measurement began
-----
60110b Noz level offset teaching
Nozzle on Head is not placed
-----
601301 Noz stocker offset teaching
Error of coordinates calculation(XY)
-----
4OM-1842
3-1441701-005