Warning Indication - Overflow on Lower
Collection Tray (Auto Shutdown)
YES
NO
Are there any condensate leaks?
Check ACU condensate drain hose is not
blocked or kinked. Check condensate
container yellow drain cap is securely fitted
and its O ring seal is in place.
Rectify leak and empty Condensate
Container and Flood Sensor cap.
Remove the green Connector from
CN10.
Does this clear the fault indication?
Is there continuity between the two
Flood Sensor probes?
YES
Ensure all moisture is removed from
around the probes and the rubber
insulating grommets are in place.
Rectify continuity fault and reconnect
CN10.
Fault indication cleared?
Replace Control PCB
Part No. 181984
Replace Flood Sensor Cap
YES
NO
NO
NO
Refit Flood Sensor Cap
YES
Use TCM CCT DWG 181948 as reference for further
fault finding.
www. .comasm-smt
ASM
Website
ASM
LinkedIn
ASM
Facebook
ASM
YouTube
SMT
Blog
ASM Assembly Systems Weymouth Ltd
11 Albany Road, Granby Industrial Estate, Weymouth | Dorset DT4 9TH England | Phone: +44 (0)1305 7670760 Email: sales@asmpt.com
Part No: | All rights reserved | © 2020 ASM Assembly Systems Singapore Pte Ltd Group
The information in this brochure contains only general descriptions and/or performance features which may not always apply to concrete products as described or which may
change as a result of technical developments and advances. Any specific performance features and/or capabilities will only be binding if contractually agreed upon.
All product names are brands or trademarks of ASM Assembly Systems or other suppliers. Their use by third parties may violate the rights of their owners.
88181945-01-06