Test Research, Inc . TR7600 SII I Series User Guide – I nstallation 6 8) Before deplo y ing the fork lif t, you c an bend the protruding s teel eyelet shown below to horizontal positi on using a hammer so that you c an m…

100%1 / 38
Test Research, Inc.
5 TR7600 SIII Series User Guide – Installation
5) Release the screws of the left wall, lift the wall, and remove the wall horizontally.
Figure 6: Remove Other Walls in Sequence
6) After all walls have been removed, remove the packing materials.
7)
Loosen the two lashing straps.
Figure 7: Remove the Two Lashing Straps
Test Research, Inc.
TR7600 SIII Series User Guide – Installation 6
8) Before deploying the fork lift, you can bend the protruding steel eyelet shown below to
horizontal position using a hammer so that you can move out the machine easily.
Figure 8: Bend the Steel Eyelet Horizontally
9) Remove the inner packing materials.
Figure 9: Remove the Inner Packing Materials
Test Research, Inc.
7 TR7600 SIII Series User Guide – Installation
10) Use a knife to cut and separate the packing materials and the vacuum bag.
Figure 10: Remove the Vacuum Bag
11) Remove the vacuum bag.
Figure 11: Remove the Vacuum Bag