This Page Intentionally Left Blank IPC-7721 February 1998 6

back. Adhesive backed conductors and lands are nor-
mally heat bonded to the board surface. Replacement
conductors and lands are available in hundreds of dif-
ferent shapes.
Compatible replacement conductors and features may
also be salvaged from scrap printed wiring boards, if
necessary.
10. Gold Plating System
Plating gold edge contacts or any metal surface
requires the use of materials that may have environ-
mental and safety concerns and must be handled prop-
erly. The power applied to the plating surfaces must be
controlled accurately to expect reliable results. A good
plating systems should include; a DC power supply
with voltage and current meters, plating anodes sized
for gold edge contact plating, a solution tray to collect
the solution runoff, a support for the PC board and a
tray to hold and store the various chemicals safely.
11. Epoxy and Coloring Agents
Many repair operations require the use of high
strength, high temperature epoxies. For high tempera-
ture applications two-part epoxies offer the highest
strength, thermal resistance and durability. It may also
be important to have resists or coloring agents so that
you can restore the cosmetic appearance of the board.
It is best to cure the epoxies in an oven if possible.
12. Eyelets and Eyelet Press System
Solder plated copper eyelets and an eyelet press/setting
tool to repair damaged plated through holes may be
required.
13. Cleaning Station/System
Regardless of the Class of Product serviced, a cleaning
system that is chemically matched to the flux sys-
tem(s) in use will be essential to a satisfactory repair.
In organizations that perform procedures on Class 3
Products, it may also be necessary to have a cleanli-
ness test system in order to periodically evaluate the
ability of the cleaning system to meet the
requirements/expectations of the user. Interim or
in-process cleaning at the workstation should be used
pending completion of the procedure and the final
cleaning.
14. Tools and Supplies
Also needed are a wide assortment of hand tools
including tweezers, various pliers, files, dental picks,
cutting tools and materials such as fluxes, solders, and
other common items.
15. Conformal Coating Area
The cost, safety concerns and utility services (air
pressure/vacuum, power, venting, UV illuminations,
etc.) of equipment associated with both the removal
and application of conformal coating suggest to many
organizations that one central conformal coating and
encapsulant area be installed.
February 1998 IPC-7721
5

This Page Intentionally Left Blank
IPC-7721 February 1998
6

OUTLINE
Electrostatic Discharge (ESD) is the rapid discharge of electri-
cal energy that was created from static sources. When the
electrical energy is allowed to come in contact with or even
close to a sensitive component it can cause damage to the
component. Electrostatic-Discharge Sensitive (ESDS) compo-
nents are those components that are affected by these high
energy surges. The relative sensitivity of a component to ESD
is dependent upon its construction and materials. As compo-
nents become smaller and operate faster, the sensitivity
increases.
Electrical Overstress (EOS) is the internal result of a unwanted
application of electrical energy that results in damaged com-
ponents This damage can be from many different sources,
such as electrically powered process equipment or ESD
occurring during handling or processing.
ESDS components can fail to operate or change in value as a
result of improper handling or processing. These failures can
be immediate or latent. The result of immediate failure can be
additional testing and rework or scrap. However the conse-
quences of latent failure are the most serious. Even though
the product may have passed inspection and functional test,
it may fail after it has been delivered to the customer.
It’s important to build protection for ESDS components into
circuit designs and packaging. However, in the manufacturing
and assembly areas, we often work with unprotected elec-
tronic assemblies that are attached to the ESDS components.
This section will be dedicated to safe handling of these unpro-
tected electronic assemblies.
For that purpose, the following subjects are addressed:
2.1.1 Electrical Overstress (EOS) Damage Prevention
2.1.2 Electrostatic Discharge (ESD) Damage Prevention
2.1.2.1 Warning Labels
2.1.2.2 Antistatic Materials
2.1.3 Anti-Static Work Station
2.1.4 Physical Handling
Information in this specification is intended to be general in
nature. Additional detailed information can be found in EIA-
625, Requirements for Handling Electrostatic-Discharge-
Sensitive (ESDS) Devices
2.1.1 Electrical Overstress (EOS) Damage Prevention
Electrical components can be damaged by unwanted electri-
cal energy from many different sources. This unwanted elec-
trical energy can be the result of ESD potentials or the result
of electrical spikes caused by the tools we work with, such as
soldering irons, soldering extractors, testing instruments or
other electrically operated process equipment. Some devices
are more sensitive than others. The degree of sensitivity is a
function of the design of the device. Generally speaking higher
speed and smaller devices are more susceptible than their
slower, larger predecessors. The purpose or family of the
device also plays an important part in component sensitivity.
This is because the design of the component can allow it to
react to smaller electrical sources or wider frequency ranges.
With todays products in mind, we can see that EOS is a more
serious problem than it was even a few years ago. It will be
even more critical in the future.
When considering the susceptibility of the product we must
keep in mind the susceptibility of the most sensitive compo-
nent in the assembly. Applied unwanted electrical energy can
be processed or conducted just as an applied signal would be
during circuit performance.
Before handling or processing sensitive components, tools
and equipment need to be carefully tested to ensure that they
do not generate damaging energy, including spike voltages.
Current research indicates that voltages and spikes less than
0.5 volt are acceptable. However, an increasing number of
extremely sensitive components require that soldering irons,
solder extractors, test instruments and other equipment must
never generate spikes greater than 0.3 volt.
As required by most ESD specifications including EIA-625,
periodic testing may be warranted to preclude damage as
equipment performance may degrade with use over time.
Maintenance programs are also necessary for process equip-
ment to ensure the continued ability to not cause EOS dam-
age.
EOS damage is certainly similar in nature to ESD damage,
since damage is the result of undesirable electrical energy.
2.1.2 Electrostatic Discharge (ESD) Damage Prevention
The best ESD damage prevention is a combination of prevent-
ing static charges and eliminating static charges if they do
Product Class: R, F, C, W
Skill Level: Intermediate
Level of Conformance: High
7721
Repair and Modification of
Printed Boards and Electronic Assemblies
Revision:
Date: 2/98
Handling Electronic
Assemblies
Number: 2.1
Material in this manual was voluntarily established by Technical Committees of the IPC. This material is advisory only and its
use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the ipc.
Page1of8