12 Tg0754-PM-SO (6) The recycle conveyor is automatically moved, pitch by pitch, so that the discharged component is not piled on the previously discharged component. (7) Press the [MANUAL] switch to check the driving of…

11 Tg0754-PM-SO0206-001
5.2 Performance Check
5.2 Performance Check
(1) Set the component library data.
(2) Display the "Component Recognition Test" operation window.
Fig. 4 "Component Recognition Test" Operation Window
(3) Set the test ID, etc.
(4) Select [Pick From Fdr (Mnl)] or [Pick From Fdr (Auto)].
(5) Select [Comp. Collection].
The placement head reduces the automatic operation speed by
95% and discharges the component.
The stop time of the head during the component discharge is the
same as that of the component placement in the automatic
operation.
• When [Rejected Component Discharge Position] is set to
"AUTO", the component is discharged on the recycle conveyor
or in the component storage box (small).
• When [Rejected Component Discharge Position] is set to
"Recycle Conveyor", the component is discharged onto the
recycle conveyor. In that case, proceed to step (4).

12 Tg0754-PM-SO
(6) The recycle conveyor is automatically moved, pitch by pitch, so
that the discharged component is not piled on the previously
discharged component.
(7) Press the [MANUAL] switch to check the driving of the recycle
conveyor, if required.
Refer to "Section 6, 3.2 "Component Recognition Test"
Tab" in Volume 2 : Operation (Supervisor) in the Instruc-
tion Manual for the main machine.
Note
0206-001
5.2 Performance Check

13 Tg0754-PM-SO0206-001
6. Component Removal Procedure
6. Component Removal Procedure
6.1 Rejected Components on Recycle Conveyor
• Remove the components on the recycle conveyor before it is filled
fully with the components.
Operation Procedure
(1) Press the [MANUAL] Switch.
The recycle conveyor continues to be driven as long as the
[MANUAL] switch is ON.
(2) When the component is moved outside the safety door, remove
it by hand.
(a) When the recycle conveyor is driven automatically,
the [MANUAL] switch is not available.
(b) If the recycle conveyor gets filled with components,
an error indication appears and the [MANUAL]
switch becomes unavailable. Refer to "8.2 Trouble-
shooting after "Error" Window (Error ID)" for details.
Note