13 Tg0754-PM-SO 0206-001 6. Component Removal Procedure 6. Component Removal Procedure 6.1 Rejected Components on Recycle Conveyor • Remove the components on the recycle conveyor before it is filled fully with the compon…

100%1 / 29
12 Tg0754-PM-SO
(6) The recycle conveyor is automatically moved, pitch by pitch, so
that the discharged component is not piled on the previously
discharged component.
(7) Press the [MANUAL] switch to check the driving of the recycle
conveyor, if required.
Refer to "Section 6, 3.2 "Component Recognition Test"
Tab" in Volume 2 : Operation (Supervisor) in the Instruc-
tion Manual for the main machine.
Note
0206-001
5.2 Performance Check
13 Tg0754-PM-SO0206-001
6. Component Removal Procedure
6. Component Removal Procedure
6.1 Rejected Components on Recycle Conveyor
Remove the components on the recycle conveyor before it is filled
fully with the components.
Operation Procedure
(1) Press the [MANUAL] Switch.
The recycle conveyor continues to be driven as long as the
[MANUAL] switch is ON.
(2) When the component is moved outside the safety door, remove
it by hand.
(a) When the recycle conveyor is driven automatically,
the [MANUAL] switch is not available.
(b) If the recycle conveyor gets filled with components,
an error indication appears and the [MANUAL]
switch becomes unavailable. Refer to "8.2 Trouble-
shooting after "Error" Window (Error ID)" for details.
Note
14 Tg0754-PM-SO0206-001
6.2 Rejected Components in Component Storage Box
6.2 Rejected Components in Component Storage Box
Periodically remove components from the storage box so that the
box is not filled with components.
Operation Procedure
(1) Press the [READY] button.
The LED on the [READY] button is turned OFF and the safety
door is unlocked.
(2) Open the safety door and take out the component storage box.
(3) Remove all components from the component storage box and
return box to specified position.
(4) Close the safety door and press the [READY] button.
The safety door is locked.
(5) Press the [ENABLE] button on the operation panel within 2
seconds after pressing the [Zero (All-Axis)] button.
All devices indicated in origin information window are zeroed.
(6) During automatic operation, the operation is restarted automati-
cally.
When in pause mode, press the [START] button to restart the
operation.