IM Troubleshooting 52489101 Rev. B
This document supports Radial 88, VCD Seq 88, and Jumper Wire 88 machines.
Problem Check Comments/Corrective Action
Monitor has AC power.
Power plug is plugged into
monitor and AC assembly.
Power on, LED on.
It is possible to plug the machine monitor or some other monitor directly
into the embedded PC board in the VME chassis, bypassing the VGA
cable in the machine.
If another machine or an office PC is available, try plugging the machine
monitor into it.
Fuse or circuit breaker OK.
VGA cable connected and
good.
+5 volt DC Power Output
from power supply.
If the monitor displays the BIOS screen (test size memory), the embedded
PC and monitor are probably OK, therefore, the software or drivers are at
fa ult.
If the monitor and cable check out, the embedded PC might be defective.
Check for +5 and +12 volts at
hard drive connectors.
Check wire cables for
breakage, wrong polarity,
poor connections.
Note: The drives and embedded PC are very similar to standard PC
compatible devices and use similar troubleshooting techniques.
Check board using IM
Diagnostics
IM Diagnostics bypasses the CPU-30, which usually supervises the
operators of the motion control board. Reference the electrical drawings.
Check encoder function
Using IM Diagnostics, cause the axis to move. (Use care to not run into
another assembly or into a limit switch.)
Ax is no t fu nctio ning
properly
Ch eck axis
Try zeroin
g
the problem axis usin
g
IM Dia
g
nostics. (Use care so as not to
run into another assembly or into a limit switch.) Try swapping motion
control board or boards.
Troubleshooting Table - VME System
Displa y Monitor Bla nk
Motion Control Board
Page 8
52489101 Rev. B IM Troubleshooting
This document supports Radial 88, VCD Seq 88, and Jumper Wire 88 machines.
Troubleshooting Table - Electrical System
The following table lists possible error scenarios for the electrical system.
Probable Ca use Correc tive Action
Electric power cord disconnected from
plan t electrical outlet.
Connect power cord plug to electrical
outlet.
UPS failure Repair or replace as required.
AC Lockout Assembly failure. Repair or replace as required.
UPS transformer client breaker tripped. Investigate and reset.
Main circuit breaker has tripped. Reset Main circuit breaker.
No power to machine systems.
Troubleshooting Table - Electrical System
Indicated Trouble
Page 9
IM Troubleshooting 52489101 Rev. B
This document supports Radial 88, VCD Seq 88, and Jumper Wire 88 machines.
Troubleshooting Table - Pneumatic System
The following table lists possible error scenarios for the pneumatic system.
Probable Cause Corrective Action
Air filter sediment bowl full. Drain and clean sediment bowl.
Moisture contaminated in house air
supply.
Correct factory air supply to machine.
Drip rate set too high.
Set the drip rate as specified in the
Preventive Maintenance Schedule in the
Base Machine Procedures document.
Pneumatic system oiler failed.
Replace pneumatic system oiler and set
drip rate.
Drip rate set too low.
Set the drip rate as specified in the
Preventive Maintenance Schedule in the
Base Machine Procedures document.
O il res erv oir em pty . Refill oil res ervoir.
Pneumatic system oiler failed.
Replace pneumatic system oiler and set
drip rate.
Source air pressure too low.
Set factory air pressure to machine to
80 psi minimum.
Seals or o-rings are dry or dirty. Clean, lubricate, and replace if needed.
Control valve sluggish. Clean, lubricate, and replace if needed.
Drip rate s et too low. Adjus t drip rate as s pec ified.
Flow c ontrols set too low . Adjus t flow controls as spec ified.
O il res erv oir em pty . Refill oil res ervoir.
5
Clinc h c utter cylinder(s ) are
operating too slow.
Refer to clinch functional problems.
Perform W aiting for Cutter in
procedures.
4
Indicated Trouble
Moisture in com pres s ed air
system.
Exc es s iv e lubricant in air
system.
Insufficient lubricant in air
system.
Air cylinder(s) are operating
too slow.
Troubleshooting Table - Pneumatic System
1
2
3