故障排除Troubleshooting.pdf - 第24页
Page 22 52489101 Rev . B IM T roubleshooting This document supports Radial 88, VCD Seq 88, and Jumper Wire 88 machines. Problem: Misformed Lead(s) with Possible Burr (VCD Only) INCO RRE CT COR REC T (VCD pictured.) Cause…

Page 21
IM Troubleshooting 52489101 Rev. B
This document supports Radial 88, VCD Seq 88, and Jumper Wire 88 machines.
Problem: Clinch Leads Toed – Same Direction (VCD and Jumper
Wire)
INCORRECT
CORRECT
(VCD pictured.)
Cause
Clinch to head Y direction misalignment.
Possible Resolution
Realign Clinch to Head. Refer to Clinch to Head Alignment procedure.
Problem: Clinch Leads Toed – Opposite Directions (VCD and
Jumper Wire)
INCORRECT
CORRECT
(VCD pictured.)
Cause
Clinch not aligned to head.
Possible Resolution
Realign Clinch to Head. Refer to Clinch to Head Alignment Procedure.

Page 22
52489101 Rev. B IM Troubleshooting
This document supports Radial 88, VCD Seq 88, and Jumper Wire 88 machines.
Problem: Misformed Lead(s) with Possible Burr (VCD Only)
INCORRECT CORRECT
(VCD pictured.)
Cause
Worn cutter or cutter bushing.
Possible Resolution
Inspect and replace cutter and cutter bushing.
Problem: Misformed Lead –Various (VCD Only)
(VCD pictured.)
Cause
Lead hitting anvil/bushing.
Possible Resolution
Realign Clinch to Head. Refer to Clinch to Head Alignment Procedure.

Page 23
IM Troubleshooting 52489101 Rev. B
This document supports Radial 88, VCD Seq 88, and Jumper Wire 88 machines.
Problem: Clinch Not Tight to Board (VCD and Jumper Wire)
(VCD pictured.)
Cause
Anvil height too low.
Possible Resolution
Readjust anvil height. Refer to Anvil Height Adjustment procedure.
Cause
Improper dimensions for the component in the Component Database.
Possible Resolution
Measure the component, and fix the component definition.