ELA Generic Tooling.pdf - 第25页
MACHI NE PROG RAMMI NG STAGE 5 D - MULTIFLEX TOOLING User Manual 1.39 NOTE Ensure th at Generic T ooling is set to Enable d in Set Prefs. 6. If th ere is a sc reen loaded continue w ith S tep 7. If there is no screen loa…

MACHINE PROGRAMMING
STAGE 5D - MULTIFLEX TOOLING
1.38 User Manual
STAGE 5D - MULTIFLEX TOOLING
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
CAUTION
BOARD CLAMPS.
Care must be taken to ensure that the board clamps are
not damaged when removing or replacing tooling.
NOTE
Setting up the MultiFlex tooling is to be performed off the machine.
1. Create a box the same size as the board using the side plates.
2. Use the board width and board length dimensions to position the box
correctly.
3. Place the PCB on a flat surface, component side up.
4. Position the acetate template, supplied with the tooling, over the PCB such
that the front edge of the board is aligned with the arrow indicators on the
template. Ensure that the centreline of the board is aligned with the template
zero.
5. Using the grid co-ordinates marked on the template, position pins which
coincide with gaps between the underside board components.

MACHINE PROGRAMMING
STAGE 5D - MULTIFLEX TOOLING
User Manual 1.39
NOTE
Ensure that Generic Tooling is set to Enabled in Set Prefs.
6. If there is a screen loaded continue with Step 7. If there is no screen loaded
go to Step 13.
7. Select Change Screen (F5). The message ‘Open Front Cover and
Remove Screen’ is displayed.
8. Raise the machine shutter, lower drop down panel.
9. Toggle screen clamp switch to the up position (Off) (fixed width chase only).
10. Remove the stencil from the printer.
11. Raise the drop down panel, lower machine shutter.
12. Press the System button.
13. Select Change Tooling (F6). The print carriage and the under screen
cleaner are moved to the rear.
The Change Tooling Parameters window is displayed:
NOTE
If the remote board stop is fitted the Board Stop X and Board Stop Y
parameters are replaced by Remote Board Stop X.
14. Setting up the board stop position is automatically done using the board
dimensions previously set in the product file. If they need adjustment to re-
position the board stop for any reason, ie any routing on the board edge or
a badly positioned image on the stencil, this can be done now. If adjustment
is necessary continue with Step 15. If adjustment is not necessary go to
Step 20.
15. Select Adjust (F1).
16. Use the Next and Previous keys (F4 - F5) to highlight each parameter.
Mode
Load
Data
Edit
Data
Setup
Squeegee
Change
Screen
Change
Tooling
Change
Language
Exit
Mode
Load
Data
Edit
Data
Setup
Squeegee
Change
Screen
Change
Tooling
Change
Language
Exit
Change Tooling Parameters
BOARD WIDTH
BOARD STOP X
BOARD STOP Y
UNDER CLEARANCE
216.0
125.0
142.6
19.0
mm
mm
mm
mm
Adjust
Open
Cover
Home
Cleaner
Board
Stop
Full
Width
Load
Width
Generic
Tooling
Exit
Save Next Previous Incr. Decr. Exit

MACHINE PROGRAMMING
STAGE 5D - MULTIFLEX TOOLING
1.40 User Manual
17. Use the Incr. and Decr. keys (F6 - F7), or the forward slash key (/) on the
keyboard, to change the parameter value.
18. Select Save (F2). The message ‘Saving fiducial data - Please wait Board
data file saved’ is displayed.
19. Select Exit (F8).
20. Select Full Width (F5). The message ‘Checking for a board on the belts’
is displayed. Whilst the rear rail is moving the following message ‘Rail
moving...’ is displayed.
21. Select Open Cover (F2).
22. Raise the machine shutter, lower drop down panel.
23. The MultiFlex tooling can now be fitted into the appropriate location holes in
the tooling plate. Ensure that the tooling is placed into the correct set of
holes, taking regard of the type of screen being used and hence the position
of the fixed rail.
24. Raise the drop down panel, lower the machine shutter.
25. Press the System button.
26. Select Board Width (F5). The message ‘Checking for a board on the
Save Next Previous Incr. Decr. Exit
Save Next Previous Incr. Decr. Exit
Save Next Previous Incr. Decr. Exit
Adjust
Open
Cover
Home
Cleaner
Board
Stop
Full
Width
Load
Width
Generic
Tooling
Exit
Adjust
Open
Cover
Home
Cleaner
Board
Stop
Board
Width
Load
Width
Generic
Tooling
Exit