Technical data
SMEMA Interface - Signal Sequence
1. After switching on the station
Transport direction
Belt n Belt n+1
PCB sensor PCB sensor
Station n transports PCB
to the transfer position
Belt n running Belt n+1 stopped
BOARD AVAIL-
ABLE
Permission
Station n+1
is not ready
1
0
2. The PCB transfer has started
Transport direction
Belt n Belt n+1
PCB sensor
Station n transfers
PCB to Station n+1
Belt n running Belt n+1 running
Station n+1 expects
PCB from station n
3. PCB is transferred
Transport direction
Belt n Belt n+1
PCB sensor PCB sensor
Station n has
just transferred the PCB
Belt n stopped Belt n+1 running
Station n+1 expects PCB
from station n, but PCB
has not yet arrived.
PCB sensor
4. PCB transfer is complete
Transport direction
Belt n Belt n+1
PCB sensor PCB sensor
Station n
Belt n stopped Belt n+1 running
Station n+1
PCB arrived
Request
NOT READY
BOARD AVAIL-
ABLE
Permission
1
1
Request
NOT READY
BOARD AVAIL-
ABLE
Permission
0
1
Request
NOT READY
BOARD AVAIL-
ABLE
Permission
0
0
Request
NOT READY
To start a new PCB transfer, both signals must be "0" for at least 50 ms.

47
Technical data
Electrical Ratings and Compressed Air Supply
Electrical ratings
Supply voltage 3 x 208 V~ ± 5 %; 50/60 Hz (U.S.A)
3 x 230 V~ ± 5 %; 50/60 Hz
3 x 380 V~ ± 5 %; 50/60 Hz
3 x 400 V~ ± 5 %; 50/60 Hz (Europe)
3 x 415 V~ ± 5 %; 50/60 Hz
Fuse protection (machine) 3 x 32 A (3 x 208 VAC / 3 x 230 VAC)
3 x 16 A (3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC)
Fuse protection (SWS) 3 x 16 A (3 x 208 V~ / 3 x 230 V ~ / 3 x 380 V~ / 3 x 400 V~ / 3 x 415 V~)
Nominal apparent power SIPLACE CA4: 4.7 kVA
SIPLACE CA3: 4.1 kVA
SWS: 0.7 kVA
Rated current consumption SIPLACE CA4: 11,3 A / 3 x 400 V~
SIPLACE CA3: 9.7 A / 3 x 400 V~
SWS: approx. 1.8 A / 3 x 400 V~
Power failure max. 20 ms
Compressed air supply
Compressed air ratings
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connection R 3/4" internal thread (pipe thread) with 1/2" hose connector
Vacuum pump (SWS)
a
a) A vacuum pump is available as an option for the placement head (see also: Retrofit Guide for Vacuum Pump
[00195089-01])
The vacuum pump is integrated into the SWS.
End vacuum: 100 mbar abs
b
Startup: against vacuum
b) Measured with air at 20°C.
Type of machine Placement head configuration Compressed air
consumption
c
without vacuum pump
c) Under normal atmospheric conditions at 20°C and 1013 hPa
SIPLACE CA4
SIPLACE CA3
C&P20CA / C&P20CA / C&P20CA / C&P20CA
C&P20CA / C&P20CA / C&P12CA / C&P12CA
C&P20CA / C&P20CA / C&P6CA / C&P6CA
C&P20CA / C&P20CA / C&P6CA / C&P12CA
C&P20CA / C&P20CA / C&P20CA
C&P20CA / C&P20CA / C&P12CA
C&P20CA / C&P20CA / C&P6CA
990 Nl/min
970 Nl/min
970 Nl/min
970 Nl/min
780 Nl/min
760 Nl/min
760 Nl/min
Compressed air specification
Particle size 5 µm
Particle density 5 mg/m³
Maximum oil content
(class 1)
Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint + 3°

48
Technical data
Electrical Ratings, Interfaces and Compressed Air
Connection
12
43
PC and LAN
connection
Power connector
5 x 6 mm² cable with CEKON plug 5 x 32 A
(3 x 208 VAC / 3 x 230 VAC)
5 x 4 mm² cable with CEKON plug 5 x 16 A
(3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC)
Compressed air connection
SMEMA/Siemens interface