7 First Booting after Installation
When a machine is booted for the first time after installation, the station software detects for the
most part independently which hardware components are used via the Auto-Configuration
feature. Certain settings, such as CAN card type, table type, lamp indicators and pin magazines
cannot be detected automatically and will have to be selected manually.
Generally, the operator will be prompted to confirm or reject any configuration changes.
By clicking the + sign in front of the auto-configuration text, the message list opens and the used
hardware components are displayed.
The Machine service activity level is required to execute the auto-configuration. The activity level
can be changed under Settings – User.
Required manual entries
The entries to be selected manually in the Value column are tagged with a '?' (question mark). All
these values have to be adapted before the auto-configuration can be finished.
As of station software version 705.03 you will have to set, whether the lamp indicators on the
placement machine towers shall be displayed two-colored (green / white) or three-colored (green /
white / red) for all placement machines of the SX-series and DX-series. More information about the
two lamp indicator systems can be found in the Feature Description of the station software, item
number [00197741-xx].
7.1 X-Series Placement Machines
► If the Coplan computer has been installed, you will additionally have to confirm or reject the 3D
Coplan sensor in the auto-configuration.
7.2 X-Series S Placement Machines
► When the X-Series S placement machines are booted for the first time you have to select the
CAN card (two or four CAN buses):
7.2.1 X4i S Placement Machine
► When the X4i S placement machine is booted for the first time you have to select the following
options manually:
– If a TrayStak Feeder is used, this has to be defined for each location concerned in the auto-
configuration.
– Table position (inner and outer)

Station Software Version 711.1 (R18-1) / Installation Manual 05/2018 Edition
61
7.3 SX-Series Placement Machines
The System identification calibration feature has been introduced for the SX-series placement
machines in the automatic calibration. Therefore, an additional calibration step may be required
after installation. In this case, a warning is displayed that the calibration is not up to date. This also
applies for the respective station software version in compatible mode. Proceed as follows:
► Log in on the Machine service activity level.
► Switch to the Configure, update and calibrate machine menu.
► Press the Automatic calibration button.
The following dialog box is displayed:
Figure 7-1: Calibration steps dialog box
► Select the System identification calibration step.
Or
► Select Selection – Gantry axes calibration.
All required calibrations will then be performed for the main axes and the machine provided
with the current data.

Station Software Version 711.1 (R18-1) / Installation Manual 05/2018 Edition
62
7.3.1 SX1/SX2 (V2) Placement Machine
► When the SX1/SX2 (V2) placement machine is booted for the first time you have to select the
following options manually:
– Table configuration for both locations.
– If the manual tray Carrier SX is used, the insert frame with the fold-away tape guide
channel is required. For this, the 60 slots (outer position, fold-away tape duct) table
configuration has to be selected for each location concerned. Thus, the 27x27 reject bin
and the left reject channel on the location are excluded from the configuration.
CAUTION
If this setting is not made, the component may be rejected over the tray and the Z axis
may dash hard against the tray.
► If the Coplan computer has been installed, you will additionally have to confirm or reject the 3-D
Coplan sensor.
7.3.2 SX+ Placement Machine
If the SX+ placement machine is to be used without gantries, this has to be configured in the auto-
configuration after the machine has been booted.
► For this, select Ignore gantries at the processing area in the machine configuration dialog.
7.3.3 SX4 Placement Machine
► When the SX4 placement machine is booted for the first time you have to select the SX4
Flexible entry for Machine frame manually in the auto-configuration, if there are tables in outer
position in processing area 2, as this is not detected automatically via sensors.
Tables in outer position are used when stationary cameras are in use.
► Otherwise you select the SX4 High Speed entry.
7.4 DX-Series Placement Machines
► When the DX placement machines are booted for the first time you have to select the following
options manually:
– For C&P12 placement head: height position (altitude)
– Lamp indicators (two-colored or three-colored)
– Table position:
inner 60 tracks
outer 60 tracks
outer with 30 tracks + free location for tray or WPC