00196430-0102-AI_Head_Reconfiguration_Kit_SX_CPP_en_de.pdf - 第46页
Introduction Abbreviations Safety Instructions for the Gantry 46 Assembly Instructions / Montageanleitung Head Reconfiguratio n Kit CPP Abbreviat ions 1.3 Abbreviations Abbreviations Description PA Placement ar ea CO Com…
Introduction
Safety Instructions for the Gantry Preparatory Work...
Assembly Instructions / Montageanleitung Head Reconfiguration Kit CPP 45
employees that the machine is de-energized for servicing. The tag or label must be securely fas
-
tened, it must be placed in a position visible to all and it may only be removed by the person who
attached it.
► Release of stored energy
Stored energy in the compressed air supply or electrical energy in electrolytic capacitors must be
released by appropriate means.
⇨ After switching off the machine, wait until the voltages and the compressed air have discharged,
so that work can be performed without any risk.
► Testing the lock out.
Testing the lock out can be done simply by pressing the start button.
► The following steps must be taken to restore the machine to operation.
► Check the working area. Authorized employees should remove all of their tools and reinstall all safety
features.
► Notify all affected employees.
► Before removing even one lock or tag, inform all workers in the affected area that the machine is
going to be restarted.
► Remove locks/tags
► Every authorized employee must remove his own lock and shut it away.
► Turn the machine on. Make sure that authorized staff check the equipment in operation to ensure
that repairs were done correctly
Testing
Service personnel may test circuits by energizing them briefly without suspending the Lock Out / Tag
Out Procedure. This may only be done when no other work is being performed by any other person on
the equipment being tested.
It is extremely important that all remote start switches be tagged with the "Do Not Operate" tag to prevent
inadvertent operation of the equipment during these periods.
Responsibilities
▪ It shall be the responsibility of the maintenance and service personnel to make sure this procedure
is adhered to.
▪ It shall be the responsibility of the maintenance and service personnel's immediate supervisor to in
-
struct his personnel on this procedure.
▪ It shall be the responsibility of the Safety Officer with assistance from the Safety Committee, Health
Service Department, and the various managers and vice-presidents to administer the Lock Out / Tag
Out Procedure.

Introduction
Abbreviations Safety Instructions for the Gantry
46 Assembly Instructions / Montageanleitung Head Reconfiguration Kit CPP
Abbreviations
1.3 Abbreviations
Abbreviations Description
PA Placement area
CO Component
COT Changeover table
COT-i Changeover table – insert (component trolley feed device)
C&P Collect&Place
C&P12 Collect&Place head with 12 segments
C&P20 Collect&Place head with 20 segments
C&P6 Collect&Place head with 6 segments
CPP Collect&Pick&Place head
ESD Electrostatic sensitive device
EMC Electromagnetic compatibility
PCB Printed circuit board
P&P Pick&Place
SC Station computer
TH TwinHead
VS Vision system
WPC Waffle pack changer
WPC4 Waffle pack changer version 4
WPC 5 Waffle pack changer version 5

Brief Description
Reconfiguration Kit CPP SX1/2 [00519983-xx] Scope of Delivery
Assembly Instructions / Montageanleitung Head Reconfiguration Kit CPP 47
Brief Description
2 Brief Description
Scope of Delivery
2.1 Scope of Delivery
▪ Reconfiguration Kit CPP, SX1/2 [00519983-xx]
▪ Placement head CPP without camera [03053528-xx]
▪ Depending on customer request:
Component camera C&P (type 29) 27x27 digital RK [03018637] or
01005 camera for CPP head [00119783-xx]
▪ When exchanging a TwinHead by a CPP head:
Additional parts set for TwinHead to CPx
Reconfig uration Kit CPP SX1/2 [00519983-xx]
2.1.1 Reconfiguration Kit CPP SX1/2 [00519983-xx]
Additional Parts Set TwinHead t o CPx
NOTICE
The camera type is added during the configuration query of the head reconfiguration kit.
The C&P component camera (type 29) 27x27 digital RK [03018637-xx] is the default.
1 x 00196430-xx Assembly Instr. Head Reconf.Kit CPP, SX 1/2
1 x 03053528-xx CPP placement head without camera
1 x 03083927-xx
includes
Parts set CP20 to CPP
3 x 03066107-xx Nozzle magazine type 20xx
1 x 03065782-xx Nozzle magazine type 28xx
2 x 03063238-xx Bin left
1 x 03065971-xx Cable set CPP / B series
2 x 00201583-xx DIN 125-A 2.7-140HV-A2
2 x 03042531-xx ISO 4762 - M 2.5 x 4-A2-70
8 x 03042541-xx ISO4762-M3x6-A2-70
2 x 03069093-xx ISO 4762 - M 3 x 50-8.8, zinc, TFP
1 x 03077179-xx
includes
Hose system FHE / CPP SX1/2
2 x 03077181-xx Air hose FHE / CPP SX1/2
2 x 00330249-xx Plug QSC-4H
1 x 03015210-xx Plug QSC-12H
1 x 03006728-xx Cover cap D Di8,0 H15 soft PVC
2 x 03079581-xx
includes
Downholder left cplt, SX1/2
1 x 03079173-xx Downholder left, SX1/2
2 x 00313069-xx DIN912-M4 x 10-A2-70
2 x 03042552-xx ISO 4762 - M 4 x 10-A2-70