00196430-0102-AI_Head_Reconfiguration_Kit_SX_CPP_en_de.pdf - 第69页
Installing the CPP Placement Head Height Adjustment and Installatio n of the Nozzle Station Assembl y of the CPP Placement Head Assembly Instructions / Montageanleitung Head Reconfiguration K it CPP 69 Installing the Noz…

Installing the CPP Placement Head
Assembly of the CPP Placement Head Height Adjustment and Installation of the Nozzle Station
68 Assembly Instructions / Montageanleitung Head Reconfiguration Kit CPP
3.4.7 Height Adjustment and Installation of the Nozzle Station
The nozzle station [03073328-xx] is included in the parts set.
When replacing a C&P20A head by a CPP head and vice versa the present nozzle station can be kept.
When replacing a TwinHead by a CPP or a C&P20A head the nozzle station of the parts set must be
installed.
Height Adjustment of the No zzle Station
3.4.7.1 Height Adjustment of the Nozzle Station
CAUTION
► If the COT insert has been removed or shifted during the conversion, the installation height
of the nozzle station should be checked in any case.
Measuring the height of the nozzle station
► Push the placement head to be measured outwards.
► Place the caliper perpendicularly on the contact sur
-
face of the reject station (1) and measure the dis
-
tance to the guide rail of the gantry.
This distance must be 189mm ± 0.2mm (2).
► If the distance is correct, proceed with the installation
of the nozzle station.
Position for the shim plates
► If the distance is too large, insert shim plates: Shim
plates for nozzle stripping device [03039514
-
xx and
03021079-xx], screws DIN7991 M4x20 - 8.8
[00333782
-
xx].
► If the distance is too small because shim plates have
already been inserted, remove these.

Installing the CPP Placement Head
Height Adjustment and Installation of the Nozzle Station Assembly of the CPP Placement Head
Assembly Instructions / Montageanleitung Head Reconfiguration Kit CPP 69
Installing the Nozzle Station
3.4.7.2 Installing the Nozzle Station
► Remove the downholder on the right above the reject bin.
► Fit the nozzle station [03073328-xx] with two screws in its mounting position (1).
► Depending on the machine configuration (see "3.4.7.3.1 Configurations with Reject Bins and Coding
Sheet" [ ➙ 70]) insert the reject bin [03048638-xx] and the component reject bin up to 6x6
[03062378--xx]. The reject bin mustn't be higher than the conveyor side wall in any case.
► Fasten the downholder left [03079173-xx] above the reject bin [03048638-xx] (see "3.4.7.3.2 Install
-
ing/Removing Downholder" [ ➙ 73]).
► Insert the coding sheet at unoccupied bin locations [03083883-xx] (see "3.4.7.3.3 Installing/Remov
-
ing Coding Sheet" [ ➙ 74]).
► Install the valve for the nozzle station [03055785-xx] (4) at the COT insert using the two DIN912-
M2,5 x 16-A2-70 screws [00350291-xx].
► Replace, unless already performed, the QSC-6H plug at the solenoid valve feed control with the Y
press-fit connection with push-on socket QSY-6H-4 [03055792-xx].
► Plug the hose PUN-CM 4x0.75 / 200mm [03056096-xx] into the pneumatic connection to the nozzle
changer (5) and into the pneumatic connection of the nozzle changer (6) or close it with the plug
QSC-4H [00330249-xx].
► Plug the hose PUN-CM 4x0.75 / 135mm [03056097-xx] into the pneumatic connection to the nozzle
changer [03055785-xx] (3) and to the pneumatic connection of the nozzle changer (2).
► Connect the cable "Cable feed X series: nozzle station" [03053223-xx] which has already been con
-
nected in the COT insert with the "valve for nozzle station cplt." [03055785-xx].
► If the verify reject bin option is already installed, the sensor for this reject bin has to be installed at
another position. For this, use the metal sensor MK2 prefitted (reject bin 6x6) [03080138-xx]. For fur
-
ther information please refer to the Assembly Instructions Reject Bin SIPLACE SX1/2 [00196615-
xx].
Installing the nozzle station
Legend
1. Fixation points of the nozzle station [03073328-xx]
2. Pneumatic connection on the nozzle station
3. Pneumatic connection to the nozzle station
4. Valve for the nozzle station [03055785-xx]
5. Pneumatic connection to the nozzle changer
6. Fixing screw of the mounting plate
7. Pneumatic connection on the nozzle changer
NOTICE
The mounting plate for the solenoid valve is fastened and fixed in position with one screw only
(6). If necessary, loosen this mounting plate to install the solenoid valve.
Attention: the connector left to the solenoid valve is also fastened to this plate.

Installing the CPP Placement Head
Assembly of the CPP Placement Head Height Adjustment and Installation of the Nozzle Station
70 Assembly Instructions / Montageanleitung Head Reconfiguration Kit CPP
Installing the Downholder and the Co ding Sheet
3.4.7.3 Installing the Downholder and the Coding Sheet
Depending on the configuration of the SX machine either the reject bin [03063238-xx] with downholder
[03079173-xx] or the component reject bin up to 6x6 [03062378--xx] is used on occupied box locations.
On unoccupied bin locations the coding sheet (No Box) [03083883-xx] has to be installed.
For the description of the configurations refer to "3.4.7.3.1 Configurations with Reject Bins and Coding
Sheet" [ ➙ 70].
For the description of the installation and the removal refer to "3.4.7.3.2 Installing/Removing Downhold
-
er" [ ➙ 73] and "3.4.7.3.3 Installing/Removing Coding Sheet" [ ➙ 74].
See also
3.4.7.3.1 Configurations with Reject Bins and Coding Sheet [ ➙ 70]
Configura tions with Reject Bins and Coding S heet
Configurations with Reject Bins and Coding Sheet
SX 1 without stationary camera
Nozzle station in SP1 right, component reject bin up to
6x6 [03062378--xx] in SP1 and 2, reject bin [03063238-
xx] with downholder [03079173-xx] in SP2 left and SP1
left, coding sheet [03083883-xx] in SP2 right.