00197465-01_SM_CP20-A-M_EN.pdf - 第50页

4 Measuring Equipmen t and Tools 4.3 Setting gauge for C&P20, C&P20A and C&P20M [03045455 -xx] 50 Service Manual SIPLACE C&P20, C&P20A, C&P20M 4.3 4 . 3 S e t t in g g a u g e f o r C & P 2 0 …

100%1 / 74
4 Measuring Equipment and Tools
4.1 Universal Placement Head Mounting Rack [03056231-xx]
Service Manual SIPLACE C&P20, C&P20A, C&P20M 49
4
4 Measuring Equipment and Tools
Measuring Equipment and Tools
4.1
4.1 Universal Placement Head Mounting Rack [03056231-xx]
Universal Placement Head Mounting Rack [03056231-xx]
4.2
4.2 Calibration Tool [03034148-xx]
Calibration Tool [03034148-xx]
The universal placement head mounting rack is suitable
for TwinHead, C&P20, CPP, IC and DLM heads.
Use:
The calibration tool is used for the following placement
heads:
C&P20
C&P20A
C&P20M
CPP (only at X4i S without stationary camera)
4 Measuring Equipment and Tools
4.3 Setting gauge for C&P20, C&P20A and C&P20M [03045455-xx]
50 Service Manual SIPLACE C&P20, C&P20A, C&P20M
4.3
4.3 Setting gauge for C&P20, C&P20A and C&P20M [03045455-xx]
Setting gauge for C&P20, C&P20A and C&P20M [03045455-xx]
Contents of "kit for setting C&P20 jaws" [03058847-xx]:
Jaw setting gauge with 2x hexagon socket-head screw M2.5x12 mm [03045455-xx]
4 x feeler gauge 0.01 mm [03058840-xx]
Feeler gauge 0.04 mm [03058839-xx]
Hose piece D12 length 20 mm [03058392-xx]
Rubber hose to protect the component sensor
10x dead indexing plate [03013091-xx]
4.4
4.4 Antistatic Tweezers
Antistatic Tweezers
1. Side stop for jaws
2. 2a and 2b: contact surfaces for jaws
3. Centering pins for accurate setting to raceway
4. Gauge fixture on raceway (screws --> M2.5x12 mm)
This setting gauge is used to set the head distance from
the raceway to the jaws on the Z axis.
1. Antistatic tweezers, type Bernstein 5
-
192
[00377393
-
xx]
2. Antistatic tweezers, type Bernstein 5
-
195
[00377394
-
xx]
5 Settings
5.1 Overview of Spare Parts and Settings for C&P20A
Service Manual SIPLACE C&P20, C&P20A, C&P20M 51
5
5 Settings
Settings
5.1
5.1 Overview of Spare Parts and Settings for C&P20A
Overview of Spare Parts and Settings for C&P20A
Description (spare part) Tools Values
Component Camera Calibration tool
Allen key
Measuring the digital component camera
Digital Vacuum Generator. CACCIA Firmware download possible
Read unit Z axis (not spare
part)
Feeler gauge 0.4 mm 0.4 mm between incremental encoder
and incremental scale
Complete Z drive
Incremental encoder
Linear motor
Allen key During assembly, press the Z drive against
the stops.
Determine the zero point correction for Z
axis and star.
Z axis return unit Move the return unit actuator to its end stop,
so that the Z axis is in the top position and
the star can be rotated.
Light barrier Z axis down (not
spare part)
Test probe 1.0 mm Distance 1,0 mm
Component sensor Check function
Firmware download possible
Silencer 10 mm open-end
wrench
None
Vacuum holding circuit, com
-
plete
Vacuum generator
Silencer
Special screw
10 mm open-end
wrench
Allen key
Segment with DP drive Nippers with plastic tips
Allen wrench
Settings: none; firmware download possible;
calibrate segment offset (top, bottom).
Star carrier, complete (not
spare part)
Allen key Determining the star and Z zero point cor
-
rection.
E/D transformer (collector ring)
assembly (for SIPLACE Ser
-
vice only)
Allen key Determining the Z and star zero point cor
-
rection.