00197465-01_SM_CP20-A-M_EN.pdf - 第67页
6 Description of the Circuit Boards 6.1 Intermediate distributor C&P20 [03002942-xx] Service Manual SIPLACE C&P20, C&P20A, C&P20M 67 6 6 D e s c r ip t io n o f t h e C ir c u it B o a r d s Description o…
5 Settings
5.6 Transferring the head specific data 5.6.2 Transferring the Head-Specific Data (from SW701)
66 Service Manual SIPLACE C&P20, C&P20A, C&P20M

6 Description of the Circuit Boards
6.1 Intermediate distributor C&P20 [03002942-xx]
Service Manual SIPLACE C&P20, C&P20A, C&P20M 67
6
6 Description of the Circuit Boards
Description of the Circuit Boards
6.1
6.1 Intermediate distributor C&P20 [03002942-xx]
Intermediate distributor C&P20 [03002942-xx]
03002942-09
LED [03002942-09]
1. Intermediate distributor board on C&P20(A) head
LED Color Status Signal name Description
D3 GN ON 5V+ +5VDC operating voltage
D4 YE ON Z_BOTTOM Z bottom sensor activated
D5 YE ON Z_TOP Z top sensor activated
D6 GN ON 15V+ +15VDC operating voltage
D8 GN ON 15V- -5VDC operating voltage
V2 GN ON V4_OUT Z valve activated
V11 YE ON EN_FESTO Return cylinder activated
V14 GN ON 24V+_VHS +24VDC operating voltage, VHS
V15 GN ON 24V+_DP +24VDC operating voltage, DP

6 Description of the Circuit Boards
6.1 Intermediate distributor C&P20 [03002942-xx]
68 Service Manual SIPLACE C&P20, C&P20A, C&P20M
Dip switch S1 [03002942-09]
Dip switch S2 [03002942-09]
Further Information
V17 YE ON Potential difference between GND and
GND_VHS present
V18 YE ON Potential difference between GND and
GND_VHS present
V106 RD ON 24V+_VHS Error in the 24VDC power supply, VHS
Switch Status Signal name Description
S1.1 OFF CAN_ID CAN_ID signal for return unit deactivated
S1.2 ON CAN_TEST -
Switch Status Signal name Description
S2.1 OFF Q1 Do NOT bypass Q1
S2.2 ON Z_BOTTOM Light barrier Z bottom
LED Color Status Signal name Description
Intermediate distributor
The following supply voltages and signals are routed by
the intermediate distributor to the individual placement
head modules or to the head board:
1. LEDs show the operating voltages on the head and
the sensor states
▪ Connector X1, 40-pole: connected to connector X1
on the head adapter board
▪ Connector X2, 40-pole: connected to connector X2
on the head adapter board
▪ Connector X3: connection for the star motor
▪ Connector X4: connection for the star incremental en
-
coder
▪ Connector X6: connection for the Z axis incremental
encoder
▪ Connector X8: connection for the Z motor
▪ Connector X9: connection for the component sensor
▪ Connector X12: connection for pressure control valve
▪ Connector X14: test connector X14_3: +5 V/X14_4:
+15 V/X14_5: -15 V/X14_7:24 V for DP motors
▪ Connector X15: connection for return unit
▪ Connector X16: internal CAN bus C&P20A