03_SM481_Service Manual Installation.pdf - 第15页
T ransfer & Installation Pr ocedur e 3-1 1 3. In stall the keybo ard bra cke t on the upp e r fr on t cove r a nd install the key boar d, mo use, etc. 3.1.5. Pneum atic Pressure Setup and Cable Connection 1. Conne ct…

Advanced High Speed Flexible Mounter
3-10
3.1.4. Installation of Parts
3.1.4.1. Required Tools
T-wrench (other tools supplied) or hex wrench
Gear wrench or torque wrench
Gear wrench or torque wrench
3.1.4.2. Part list
Tower lamp
Mouse and mouse pad
Keyboard
Monitor and monitor stand
3.1.4.3. Part Installation Procedure
1. Install the monitor base after leveling and install the monitor by connecting the connector on
the upper part of the machine. (Tighten all bolts when assembling the monitor unit.)
2. Connect the connector at the left inside the machine and signal light connector and secure the
signal light at the left on the upper part with fixing bolts (4 sets).
Signal Light

Transfer & Installation Procedure
3-11
3. Install the keyboard bracket on the upper front cover and install the keyboard, mouse, etc.
3.1.5. Pneumatic Pressure Setup and Cable Connection
1. Connect pneumatic hose to the left fitting of the air filter. At this time, Check if the air filter is
installed or not in the air main source device.
Monitor
Keyboard Stand

Advanced High Speed Flexible Mounter
3-12
2. Turning the knob of the regulator, adjust the air pressure to 0.45 ~ 0.55 MPa. (The air
consumption of this machine is max. 300 Nℓ/min.) At this time, the outside diameter of the
pneumatic hose greater than 12mm is recommended.).
Caution
If the pneumatic pressure exceeds 0.45~0.55 Mpa, a problem may
occur in the part pickup and placement and feeder movement.
Therefore, check the pneumatic pressure before performing the
work. A compressor with appropriate capacity for the pneumatic
consumption of the machine must be used. Otherwise, the
reduction of the pneumatic pressure in the machine has influence
on the part placement quality.
Caution
Oil leakage into the pneumatic pipeline due to the compressor
being too old may cause fatal errors in each machine. Foreign
matters like chips and burs remain inside the pipe once piping
work is completed. Therefore, it is recommended to flush the
piping with the pipe ends being covered with a clean cloth. If the
cloth remains clean and there is no sign of contamination, after a
series of flushings,
then connect the pneumatic pipe to the machine. Check if the air
dryer has been installed to prevent moisture condensing inside the
pipe.
In order to prevent the oil inlet into the pipes and freezing to occur,
check if the oil filter and air dryer are installed.
Pressure increase
(clockwise)
Pressure
reduction
(counterclockwise)