20 6-monthly CPP Appendix: Maintain the holding circuit 45 min 1 / 2 CAUTION!Refer to safety instructions in user manual before commencing Mainten- ance NOTICE! ESD guidelines are to be followed Tool: T22, T38, T57, T92…

100%1 / 70
20 6-monthly CPP Appendix: Maintain the holding circuit 45 min 1 / 2
CAUTION!Refer to safety instructions in user manual before commencing Mainten-
ance
NOTICE! ESD guidelines are to be followed Tool:
T22, T38, T57, T92
Wear Part:
W29
Consumables:
C5, C19, C22, C24, C31, C45
1 Remove the bottom seal. 2 Remove the top seal. 3 Clean the holding circuit from rough pollu-
tion.
4 Put the holding circuit into the ultrasonic
bath. Cleaning liquid = 5% C24 and 95%
C45, temp = 50°C, time = 30min.
5 Prepare the multipette. See appendix
"Prepare the multipette".
6 When finished rinse all holes from the top
using a complete filling.
20 6-monthly CPP Appendix: Maintain the holding circuit 45 min 2 / 2
CAUTION!Refer to safety instructions in user manual before commencing Mainten-
ance
NOTICE! ESD guidelines are to be followed Tool:
T22, T38, T57, T92
Wear Part:
W29
Consumables:
C5, C19, C22, C24, C31, C45
7 Rinse then holes from the bottom starting
with the outer holes using a complete
filling.
8 Dry the outer holes from top and from the
bottom. Ensure to keep a distance and be
careful not to hit the index pin.
9 Clean-up the multipette. See "Appendix:
Clean-up the multipette".