Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
40
2.5 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with mains voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being switched on again. The procedure is described in the “Locking the machine…” section of
the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2.5.1 Definitions
2
PLEASE NOTE 2
2
2

Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
41
2.6 Conversion
2
The conversion must only be carried out by SIPLACE service engineers. 2
2
2
2.6.1 Moving the machine zero point
To be able to set the conveyor on the HS-60 / D4machine type to its maximum conveyor width
(Wide), it is first necessary to move the machine zero point. The hardware must be converted by
a service engineer in order to do this. The following sequence should also be followed in order to
return the machine zero point to its previous default position. 2
2
Description of the mechanical conversion for the machine zero point (picture) 2
2
There are already holes for moving the angle unit exactly 25 mm to the outside. Only two of the 4
screws have to be removed (the 2 screws marked with a red dot are for fitting and remain fixed).
Move the angle units and tighten the 2 screws. 2
2
Fig. 2.6 - 1 Illustration of the need to convert the hardware
2

Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
42
2
Fig. 2.6 - 2 Illustration of important vectors for moving the machine zero point
2
: Check the "Conveyor zero point" entry
in the C:\SrDaten\SrcMa
directory in the "real.ma" file:
The conveyor zero point should have the following value, depending on the software version:
Enter the correct value if this is not the case.
: Switch the placement machine off at the main switch.
The software changes take effect when the machine is switched on again.
2
2
2
2
2
2
from version 505.03 onwards M18 674080
for older versions 671580