00194579-0202.pdf - 第55页
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4 08/2006 Edition 57 This is clearly illustrated in the following table which contains an overview of the possible mapping widths. 2 T ab. 2.6 - 1 Guidelines…
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
56
2.6.7 Calibrating the machine after changing the extended conveyor configuration
"Position of stationary side wall“
Once the extended conveyor configuration "Position of stationary side wall“ has been moved,
there are certain calibration tasks that must be carried out to ensure that the machine operates
smoothly. 2
: Switch to the SITEST program.
: Switch to the "Gantries" view. ==> "Gantry functions".
Carry out a reference run.
: Switch to the "Gantries" view. ==> "Calibrate position".
Teach the PCB reference corners.
: SITEST main view:
Select "Settings" ==> "Save machine data".
: Carry out a full reference run.
: Switch to the view "Calibrate machine“ ==> "Calibrate conveyor side walls and conveyor width"
(needed when you set up the "Wide HS-60“ for the first time).
To be able to determine the precise position of the height reference run, you must first teach the
PCB reference corners. 2
: Calibrate the conveyor side walls and conveyor width for determining the maximum conveyor
width.
2.6.8 PCB mapping and head mapping for machine type HS-60 / D4
: Carry out the PCB mapping for machine type HS-60 / D4 in order to improve the placement
accuracy.
: If the machine zero point is on the inside, mapping widths 216 mm and 380 mm are suggested
for the dual conveyor and 460 mm for the single conveyor. If the machine zero point is on the
outside, mapping widths 380 mm are suggested for the dual conveyor and 508 mm for the sin-
gle conveyor.
Select the required mapping width and carry out the PCB mapping / head mapping.
2
2
2
2
2
2
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
57
This is clearly illustrated in the following table which contains an overview of the possible mapping
widths. 2
Tab. 2.6 - 1 Guidelines for the mapping widths for various machine types for platform 2
2.6.9 Carrying out the MFU
After changing the extended conveyor configuration "Position of stationary side wall“ ==> "Stan-
dard width“ / "Wide“, carry out the fine calibration (or MFU) because the calibration points will have
moved with the PCB reference corner. 2
Machine type 2 Single conveyor [mm] 2 Dual conveyor [mm] 2
HF series 2 508 2 215/450 2
S-27 HM 2 460 2 215/380 2
HS-60 / D4, machine zero point "inside“ 2 460 2 215/380 2
HS-60 / D4, machine zero point "outside“2 508 2 215/380 2

Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
58
2.7 Attaching the warning labels
2.7.1 Positions of the warning labels 242mm / 508mm
2.7.1.1 Label 1
Centrally beneath the track rule on the feeder cover plate at each location (105mm x 41mm): 2
2
2
2
Use S-Feeders only with 242/506 option
Warning label