Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4 08/2006 Edition 58 2.7 Att aching the warning labels 2.7.1 Positions of the wa rning labels 242mm / 508mm 2.7.1.1 Label 1 Centrally beneath the track ru le…

100%1 / 62
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
57
This is clearly illustrated in the following table which contains an overview of the possible mapping
widths. 2
Tab. 2.6 - 1 Guidelines for the mapping widths for various machine types for platform 2
2.6.9 Carrying out the MFU
After changing the extended conveyor configuration "Position of stationary side wall“ ==> "Stan-
dard width“ / "Wide“, carry out the fine calibration (or MFU) because the calibration points will have
moved with the PCB reference corner. 2
Machine type 2 Single conveyor [mm] 2 Dual conveyor [mm] 2
HF series 2 508 2 215/450 2
S-27 HM 2 460 2 215/380 2
HS-60 / D4, machine zero point "inside“ 2 460 2 215/380 2
HS-60 / D4, machine zero point "outside“2 508 2 215/380 2
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
58
2.7 Attaching the warning labels
2.7.1 Positions of the warning labels 242mm / 508mm
2.7.1.1 Label 1
Centrally beneath the track rule on the feeder cover plate at each location (105mm x 41mm): 2
2
2
2
Use S-Feeders only with 242/506 option
Warning label
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
59
2.7.1.2 Label 2
Gantry 2 and 4 (in the vicinity of the reflector) (105mm x 41mm) 2
2
2
2
2
2
2
2
2
Attention: Option
maintenance 00194579