Chapter 5 The Twelve Stations
(2) Enter the I/O map and press [OUT], [+Page], then use the or
key to move the cursor to the item titled “Y028 PLACE SOL
ON”. Using the [ON/OFF] button change the displayed “X” to
“O”. This operation turns off station 7’s solenoid stopper. If
the solenoid is not turned off, adjustment is impossible.
(3) Attach the cam handle to the cam shaft. Turn the handle until
the cam angle indicator reads 175°.
(4) With the cam angle at 175°, adjust the adjusting rod so that
there is no space between the upper surface of the nozzle clutch
and the pusher.
Fig. 5-35 Nozzle Clutch and Pusher Gap
(Cam Angle 175°)
(5) Return the cam angle to 0°. Confirm that the gap between the
upper surface of the nozzle clutch and the pusher is 0.2 ~ 0.3
mm.
Fig. 5-36 Nozzle Clutch and Pusher Gap
(Cam Angle 0°)
5 – 34
Version 6.0
CP IV-3 Maintenance
5 – 35
Version 6.0
Chapter 5 The Twelve Stations
5.7.2 Turning the Valve ON/OFF
By activating the valve at station 7, the vacuum within the nozzle
switches from off to on (the spool is pushed) and at the same time
the air that turns on the vacuum generator is supplied. By turning
the valve off, the vacuum within the nozzle is destroyed and part
placement is made possible.
When the valve is turned on the inside of the nozzle becomes a
vacuum which enables the nozzle to pick up a part.
The operation of turning the valve on and off is driven by a cam
mechanism. The cam drives a lever, which drives a rod, which
drives a lever, which drives the slide.
The stroke of the rod is a fixed value determined by the curve of the
cam.
Fig. 5-37 Valve Activation Operation Mechanism at Station 7
Follow the procedure below to adjust the activation and
deactivation of the nozzle valve.
(1) Press [SET], [MANUAL], [I/O] and [EMERGENCY STOP] to
cut the 200V power supply but still leaving the 100V power
supply on.
(2) Enter the I/O map and press [OUT], [+Page] then use the []
or [] key to move the cursor to the item titled “Y028 PLACE
SOL ON”.
(3) Make sure the spool is pushed in.
CP IV-3 Maintenance
Chapter 5 The Twelve Stations
(4) Using the [ON/OFF] button, change the displayed “X” to “O”.
This allows the stopper to be removed enabling the shaft to
move vertically.
(5) Attach the cam handle to the cam shaft. Turn the handle until
the cam angle indicator reads 270°.
(6) Adjust so that the gap between the pushed in spool and the
pusher is 0.1 ~ 0.3 mm.
Fig. 5-38 Spool and Pusher Gap (Cam Angle 270°)
(7) Return the cam angle to 0°. Confirm that the gap between the
pulled out spool and the pusher is more than 2 mm. To adjust
the air release valve, tighten the knob completely, then turn it 5
to 5.5 revolutions.
Fig. 5-39 Spool and Pusher Gap (Cam Angle 0°)