Chapter 1
This Chapter describes the work environment and working tools for the maintenance of
the machine.
Conditions for Maintenance
Multi-Functional Placer
SM482PLUS Maintenance Handbook
1-5
Common Working Procedure before Maintenance
1. Power supply procedure
Step 1.
Main Switch On
- Power supply turned off - Power supply turned on
2. Home
Step 1.
Press the machine's 'Ready' button
1
Step 2.
Perform homing by clicking the <Home> button
2
When the machine is in 'Ready' state, it can be returned to the
origin.(homing)
Common Working Procedure before Maintenance
Chapter 1
This Chapter describes the work environment and working tools for the maintenance of
the machine.
Conditions for Maintenance
Multi-Functional Placer
SM482PLUS Maintenance Handbook
1-6
Common Working Procedure before Maintenance
Conditions for Maintenance
3. Releasing 'Emergency Stop' mode
Step 1.
Press the 'EMG' button
Step 2.
Press the 'STOP' button
Step 3.
Press the 'RESET' button
Step 4.
Press the 'READY' button
Warning
Perform checking with the power supply to the motor cut off
without fail.
Chapter 1
This Chapter describes the work environment and working tools for the maintenance of
the machine.
Conditions for Maintenance
Multi-Functional Placer
SM482PLUS Maintenance Handbook
1-7
Working Environment and Condition
Requirements for air pressure
DEF. DESCRIPTION Notes
Primary pressure 5.0 - 7.0 kgf/cm
2
Secondary
pressure
4.5 - 5.5 kgf/cm
2
Air Consumption 180 NL/min ±20 %
Vacuum Pump: 50 ±20 % NL/
min(Option)
5 kgf/cm
2
(Secondary
pneumatic standard)
Environmental conditions
DEF. DESCRIPTION
During
operation
Temperature v
Humidity
30 % - 80 % RH (non-condensation state)
Lessthan70%RH(Morethan30℃,non-
condensation state)
During
shipment or
storage (in
states other
than during
operation)
Temperature -10℃-60℃
Humidity
10 % RH - 90 % RH (non-condensation state)
Morethan35℃(Lessthawet-bulbtemperature
35℃,non-condensationstate)
Power requirements
DEF. DESCRIPTION Notes
Capacity Max. 3.5 kVA
Frequency 50/60Hz
Phase 3 Phase
Connection Y-Y
Rated Primary Voltage AC 200 ± 18 V
AC 208 ± 19 V
AC 220 ± 20 V
AC 240 ± 22 V
AC 380 ± 25 V
AC 415 ± 28 V
Permitted Voltage Drop(s)
Short Circuit Current Rating 100 KA (220 VAC)
Distribution System TN
Full-Load Current 20 A Full Load Ampere
Peak Starting Currents -
Warning
If unspecified voltage is used or power input is changed
improperly, fire could occur and a death from electric shock could
occur.
Change of power input must be done by a trained repair and
maintenance operator or our authorized C/S personnel.
Working Environment and Condition