SM482PLUS_Maintenance(Eng_Ver2.7).pdf - 第41页

SM482PLUS Maintenance Handbo ok 3-8 Chap ter 3 Daily Inspe ction Multi -Func tional Placer Cleaning the feeder and feeder base Daily Inspection Step 6 . Clea n the fe ed er bas e slot an d con nec tor us ing a flat brush…

100%1 / 78
SM482PLUS Maintenance Handbook
3-7
Chapter 3
Daily Inspection
Multi-Functional Placer
Cleaning the feeder and feeder base
Step 4.
Clean the feeder connector and the installation guide
using a brush.
Step 5.
Check visually for any foreign materials in the feeder
base slot and connector.
Caution
In case the feeder is installed on the feeder base without visually
checking and cleaning the feeder base upper surface and feeder
slot, the feeder could not be installed and removed smoothly.
Caution
When the feeder is felt stuck during the installation of the feeder
unlike normal feeling, do not apply excessive force to the feeder.
After removing the feeder, Check it visually and clean it if necessary.
SM482PLUS Maintenance Handbook
3-8
Chapter 3
Daily Inspection
Multi-Functional Placer
Cleaning the feeder and feeder base
Daily Inspection
Step 6.
Clean the feeder base slot and connector using a flat
brush.
Step 7.
Install the feeder
①Fixing the feeder in the slot
②Fixing the grip
If it is properly installed, the LED color turns green.
SM482PLUS Maintenance Handbook
3-9
Chapter 3
Daily Inspection
Multi-Functional Placer
Cleaning the Backup Table
If foreign materials such as solder enter the machine, they may cause it to fail.
Therefore, clean the Backup Table to prevent this problem from happening.
Tool for Maintenance
Ultra fine fiber cloth, Cleaning liquid
Measures
Step 1.
Select <Board> submenu of the <PCB Edit> menu of the
MMI and enter '200' for Board Size Y value and then
click the <Conv. Width> button
1
2
3
Step 1.
Move the X Frame to rear by referring to “Backward
movement of the X-frame” on page 1-4.
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to “How to perform emergency stop” on page
1-2.
Step 3.
Remove the backup pin
Cleaning the Backup Table
(Time required: 5min / No. D-4)