SM482PLUS_Maintenance(Eng_Ver2.7).pdf - 第64页

Mon thly Inspe ction Chap ter 5 Multi -Func tional Placer SM482PLUS Maintenance Handbo ok 5-1 1 Cleaning and Lubricating the Y Frame Ball screw Cleani ng and Lubri cat ing the Y Fr ame Ball scr ew T ool for M aintenanc e…

100%1 / 78
Monthly Inspection
Chapter 5
Multi-Functional Placer
SM482PLUS Maintenance Handbook
5-10
Cleaning and Lubricating the Y Frame LM Guide
Monthly Inspection
Step 4.
Inject the grease using a lubricator.
A
A
B
B
A
B
Step 5.
Move the X frames back and forth three times.
Caution
The designated grease must be applied using the designated
lubricator in the designated manner. Other lubricating methods are
unacceptable.
Caution
If the machine's operating environment is harsh, check its lubrication
status frequently.
Step 6.
Release the emergency stop as described in “Releasing
‘Emergency Stop’ mode” on page 1-6 and perform the
operation again.
Monthly Inspection
Chapter 5
Multi-Functional Placer
SM482PLUS Maintenance Handbook
5-11
Cleaning and Lubricating the Y Frame Ball screw
Cleaning and Lubricating the Y Frame Ball screw
Tool for Maintenance
Ultra-fine fiber cloth, Lubricator: MG70, GREASE: AFE-CA
Measures
Step 1.
Move the X Frame to rear by referring to “Backward
movement of the X-frame” on page 1-4.
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to “How to perform emergency stop” on page
1-2.
Step 3.
Clean the ball screw rail using an ultra fine fiber cloth.
(Time required: 20min / No. M-8)
Monthly Inspection
Chapter 5
Multi-Functional Placer
SM482PLUS Maintenance Handbook
5-12
Cleaning and Lubricating the Y Frame Ball screw
Monthly Inspection
Step 4.
Inject the grease using a lubricator.
C
C
C
C
Step 5.
Move the X frames back and forth three times.
Caution
The designated grease must be applied using the designated
lubricator in the designated manner. Other lubricating methods are
unacceptable.
Caution
If the machine's operating environment is harsh, check its lubrication
status frequently.
Step 6.
Release the emergency stop as described in “Releasing
‘Emergency Stop’ mode” on page 1-6 and perform the
operation again.